7. Instructions<br />

Program control instructions<br />

FUN<br />

No.<br />

Name Expression Function Steps Speed<br />

(µs)<br />

Page<br />

128 Subroutine call −[ CALL N. n ]− Calls the subroutine number n. 2 21.0 203<br />

129 Subroutine<br />

return<br />

⎥−−[ RET ]−⎢ Indicates the end of a<br />

subroutine.<br />

1<br />

(in a<br />

pair)<br />

204<br />

132 FOR<br />

133 NEXT<br />

−[ FOR n ]−<br />

−[ NEXT ]−<br />

When the input of FOR is ON,<br />

executes the segment from<br />

FOR to NEXT the number of<br />

times specified by n.<br />

2<br />

1<br />

22.0<br />

(in a<br />

pair)<br />

205<br />

206<br />

137 Subroutine<br />

entry<br />

⎥−[ SUBR (n) ]−−⎢ Indicates the start of the<br />

subroutine number n.<br />

2<br />

included<br />

in CALL 207<br />

140 Enable<br />

interrupt<br />

141 Disable<br />

interrupt<br />

−[ EI ]−<br />

−[ DI ]−<br />

Enables execution of interrupt<br />

program.<br />

Disables execution of interrupt<br />

program.<br />

1<br />

1<br />

27.6<br />

(in a<br />

pair)<br />

208<br />

209<br />

142 Interrupt return ⎥−−[ IRET ]−⎢ Indicates the end of an interrupt<br />

program.<br />

1 1.4 210<br />

143 Watchdog<br />

timer reset<br />

−[ WDT n ]− Extends the scan time over<br />

detection time.<br />

2 16.1 211<br />

144 Step sequence<br />

initialize<br />

−[ STIZ (n) A ]− Resets OFF the n<br />

devices stating with<br />

A, and sets ON A.<br />

These<br />

configure<br />

a series<br />

3<br />

59.9 -<br />

65.0<br />

212<br />

145 Step sequence −[ STIN A ]− Turns ON output if of step<br />

input<br />

input is ON and A is<br />

ON.<br />

sequence 2 27.0 213<br />

146 Step sequence −[ STOT A ]−⎢ When input is ON,<br />

output<br />

resets OFF the<br />

devices of STIN on<br />

the same rung, and<br />

sets ON A.<br />

2<br />

27.0 -<br />

119.0<br />

214<br />

RAS<br />

FUN<br />

No.<br />

Name Expression Function Steps Speed<br />

(µs)<br />

Page<br />

154 Set calendar −[ A CLND ]− Sets 6 registers data starting<br />

with A into clock/calendar.<br />

2 217<br />

155 Calendar −[ A CLDS B ]− Calculates difference between<br />

operation<br />

present date & time and past<br />

date & time stored in 6 registers<br />

starting with A, and stores the<br />

result in 6 registers starting with<br />

B.<br />

3 218<br />

112 <strong>T1</strong>-<strong>16S</strong> User’s <strong>Manual</strong><br />

6F3B0253<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net