FUN 165 FG Function generator<br />

Expression<br />

Input −[ A FG (n) B → C ]− Output<br />

6F3B0253<br />

7. Instructions<br />

Function<br />

When the input is ON, this instruction finds the function value f(x) for A as x, and stores it in C. The<br />

function f(x) is defined by the parameters stored in 2 × n registers starting with B.<br />

Execution condition<br />

Input Operation Output<br />

OFF No execution OFF<br />

ON Execution ON<br />

Operand<br />

Name Device Register Constant Index<br />

X Y R S T. C. XWYWRWSW T C D I J K<br />

A Input value x √ √ √ √ √ √ √ √ √ √ √<br />

n Parameter size 1 - 32<br />

B Start of<br />

√ √ √ √ √ √ √<br />

parameters<br />

C Function value<br />

f(x)<br />

Example<br />

√ √ √ √ √ √ √ √ √<br />

When R010 is ON, the FG instruction finds the function value f(x) for x = XW004, and stores<br />

the result in D0100.<br />

The function f(x) is defined by 2 × 4 = 8 parameters stored in D0600 to D0607. In this example,<br />

these parameters are set at the first scan.<br />

Basic Hardware and Function 229<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net