FUN 145 STIN Step sequence input<br />

Expression<br />

Input −[ STIN A ]− Output<br />

Function<br />

When the input is ON and the device A is ON, the output is set to ON.<br />

Execution condition<br />

Input Operation Output<br />

OFF No execution OFF<br />

ON When A is ON ON<br />

When A is OFF OFF<br />

6F3B0253<br />

7. Instructions<br />

Operand<br />

Name Device Register Constant Index<br />

X Y R S T. C. XWYWRWSW T C D I J K<br />

A Step device √<br />

Example<br />

The following sequential operation is performed.<br />

When R020 is changed from OFF to ON, R400 is set to ON and subsequent 9 devices (R401<br />

to R409) are reset to OFF.<br />

When X004 comes ON, R400 is reset to OFF and R401 is set to ON.<br />

When both X005 and R022 are ON, R401 is reset to OFF and R402 is set to ON.<br />

R020<br />

X004<br />

X005<br />

R022<br />

R400<br />

R401<br />

R402<br />

Basic Hardware and Function 213<br />