FUN 079 RTL1 1 bit rotate left<br />

Expression<br />

Input −[ RTL1 A ]− Output<br />

6F3B0253<br />

7. Instructions<br />

Function<br />

When the input is ON, the data of register A is rotated 1 bit to the left (MSB direction). The pushed<br />

out bit state is stored in the right most bit (LSB) and in the carry flag (CF = S050). After the<br />

operation, if the left most bit (MSB) is ON, the output is turned ON.<br />

Execution condition<br />

Input Operation Output CF<br />

OFF No execution OFF −<br />

ON Execution When MSB = 1 ON Set or reset<br />

When MSB = 0 OFF Set or reset<br />

Operand<br />

Name Device Register Constant Index<br />

X Y R S T. C. XWYWRWSW T C D I J K<br />

A Operation data √ √ √ √ √ √ √ √ √ √<br />

Example<br />

When X008 is changed from OFF to ON, the data of RW15 is rotated 1 bit to the left.<br />

The figure below shows an operation example.<br />

(MSB) (LSB)<br />

F E D C B A 9 8 7 6 5 4 3 2 1 0<br />

1 1 1 0 0 1 1 1 0 0 1 1 1 0 1 0<br />

CF<br />

1 1 1 0 0 1 1 1 0 0 1 1 1 0 1 0 1<br />

R002 is turned ON<br />

RW15<br />

RW15 (Result)<br />

Basic Hardware and Function 173<br />