PIP LED<br />

Use the PIP LED option to turn the display of the PIP LED on the airway display on or off. When the<br />

PIP LED is on, the Airway Pressure display LED representing the Peak Inspiratory Pressure of the<br />

previous breath remains lit during exhalation.<br />

To modify the PIP LED Setting:<br />

1) Push the Select button while PIP LED is displayed.<br />

2) PIP LED ON or PIP LED OFF is displayed.<br />

3) Turn the Set Value knob until the desired setting is displayed.<br />

4) Push the Select button.<br />

Options: ON or OFF<br />

Model Number / Serial Number<br />

Use the Model Number / Serial Number option to view the <strong>LTV</strong>’s model or serial number, and to verify<br />

LTM Graphics Monitor compatibility.<br />

To view the <strong>LTV</strong> model number:<br />

1) Turn the Set Value knob while in the VENT OP menu until <strong>LTV</strong> xxxx is displayed.<br />

• The model number is displayed as: <strong>LTV</strong> xxxx where xxxx is the model of the ventilator.<br />

• The model number is set when the ventilator is manufactured.<br />

2) Push the Control Lock button to exit, or the Select button to display the serial number option.<br />

To view the <strong>LTV</strong> serial number:<br />

1) Push the Select button when the <strong>LTV</strong> model number (<strong>LTV</strong> xxxx) is displayed.<br />

• The serial number is displayed on the left side of the display area as: xxxxxx where xxxxxx<br />

is the serial number of the ventilator.<br />

• The serial number is set when the ventilator is manufactured.<br />

2) Push the Control Lock button or the Select button to return to the model number option.<br />

To verify LTM Graphics Monitor Compatibility:<br />

1) Push the Select button when the <strong>LTV</strong> model number (<strong>LTV</strong> xxxx) is displayed.<br />

• The message LTM will be displayed on the right side of the display area if the ventilator was<br />

originally manufactured or upgraded by Pulmonetic Systems to accommodate the LTM<br />

Graphics Monitor.<br />

2) Push the Control Lock button or the Select button to return to the model number option.<br />