Event Name Code Event Associated Alarm<br />

HOME ER1 38 Stepper motor home failure occurred HW FAULT<br />

HOUR MTR 03 Set hour meter None<br />

INTRRPT1 31 Spurious interrupt occurred ms RESET 1<br />

INTRRPT2 32 Spurious interrupt occurred ls RESET 1<br />

LN VENT1 67 Shutdown for other than pressing On/Standby RESET<br />

LO f/VtT0 84 Rapid Shallow Breathing Index SBT < f/Vt<br />

LO f/VtT1 83 Rapid Shallow Breathing Index SBT < f/Vt<br />

LO PEEP0 90 Monitored PEEP LOW PEEP<br />

LO PEEP1 89 Monitored PEEP LOW PEEP<br />

LO PRES0 50 Low peak pressure exited LOW PRES<br />

LO PRES1 49 Low peak pressure occurred LOW PRES<br />

LO SBTf1 79 Total Breath Rate SBT < f<br />

LO SBTf2 80 Total Breath Rate SBT < f<br />

LOW DIS 09 Low side disconnect DISC/SENSE<br />

LOW VE 0 48 Low minute volume exited LOW MIN VOL<br />

LOW VE 1 47 Low minute volume occurred LOW MIN VOL<br />

MON f/Vt 86 f/Vt value at SBT exit N/A<br />

NEW PTNT 91 New patient setup N/A<br />

NO CAL 26 No calibration data found NO CAL DATA<br />

O2 HI 0 24 O2 pressure high exited HIGH O2 PRES<br />

O2 HI 1 23 O2 pressure high occurred HIGH O2 PRES<br />

O2 LOW 0 22 O2 pressure low exited LOW O2 PRES<br />

O2 LOW 1 21 O2 pressure low occurred LOW O2 PRES<br />

POST 57 POST failure RESET<br />

RAC ERR0 70<br />

RAC ERR1 69<br />

Recovery from problem detected with primary<br />

and/or redundant audible alarm circuitry<br />

Problem detected with primary and/or<br />

redundant audible alarm circuitry<br />

HW FAULT<br />

HW FAULT<br />

RUNAWAY 58 Code runaway detected RESET<br />

SBT0 87 SBT exit reason N/A<br />

SBT1 85 N/A N/A<br />

SET DATE 53 Date set N/A<br />

SET TIME 54 Time set N/A<br />

SNDRERR0 72 Recovery from alarm sounder error HW FAULT<br />

SNDRERR1 71 Alarm sounder error HW FAULT<br />

STACK 56 Stack overflow detected RESET<br />

SYNC ER1 36 Stepper motor lost sync occurred HW FAULT<br />

SYNCER0 37 Stepper motor lost sync exited HW FAULT<br />

TBN ESTP 46 Turbine emergency stop occurred HIGH PRES<br />

TBN HSTP 66 Turbine Hold Stop occurred HIGH PRES<br />

TBN ISTP 44 Turbine immediate stop occurred HIGH PRES<br />

TBN ZERO 45 Turbine set to zero flow occurred HIGH PRES<br />

VENT 0 02 Power off None<br />

Operator’s <strong>Manual</strong> <strong>LTV</strong> ® <strong>1200</strong> Ventilator Page E-7<br />

p/n 18247-001, Rev. G