Pendant luminaires, SiFORM for individual and continuous mounting<br />

17<br />

CAT II Modul II<br />

Luminaire module with diffuser.<br />

Cover for MUF.<br />

Luminaire module for<br />

continuous row mounting.<br />

Luminaire module without<br />

diffuser.<br />

4<br />

Accessories<br />

Mounting<br />

Code<br />

Multifunction rail 5LM 100 0-1<br />

Cover for MUF<br />

1,19m 5LM 100 0-4<br />

3,00m 5LM 100 0-2<br />

End caps for MUF 5LM 100 0-3<br />

• System overview see page 4/12.<br />

• Detailed description see page 4/13.<br />

• Dimensions see page 4/32.<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Refurbishment<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Individual CAT II Modul II luminaire<br />

Luminaire : 5LM 17 7 7 - 1 US2 with 1 x 54W and HFG ( Lumen output : 1 x 4400 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 73%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 0.9 1. 0 2.7 3. 0 4.5 5.0 6.7 7. 4<br />

30 1. 3 1. 4 3. 8 4.2 6.4 7. 0 9.6 10<br />

40 1. 6 1. 8 4.9 5.4 8.2 9.0 12 13<br />

50 2.0 2.2 6.0 6.6 9.9 11 15 16<br />

75 2.9 3. 1 8.6 9.3 14 16 22 23<br />

100 3. 8 4.0 11 12 19 20 28 30<br />

200 7. 4 7. 6 22 23 37 38 56 57<br />

500 18 19 55 56 92 93 137 139<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 42 35 40 35 38 34 34 29<br />

0.80 47 39 45 40 42 38 37 32<br />

1.00 52 43 49 44 45 41 40 35<br />

1.25 57 47 53 48 49 45 43 38<br />

1.50 61 51 57 52 52 48 46 41<br />

2.00 66 55 61 56 55 52 50 44<br />

3.00 75 62 67 64 61 58 56 50<br />

5.00 80 67 72 69 64 62 59 53<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 28W 31<br />

1 x 35W 38<br />

1 x 54W 62<br />

Light distribution to DIN 5040<br />

Conversion factor F1 for 5LM 17 7 .-..<br />

ϕ u 0.83<br />

HFG<br />

ϕ su 0.73<br />

7-1 PS2 1 x 28W 1. 79<br />

ϕ so 0.80<br />

7-1 RS2 1 x 35W 1. 43<br />

7-1 US2 1 x 54W 1. 00<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT<br />

Conversion factor F for 5LM 17 7 .-..<br />

HFG<br />

7-1 PS2 1 x 28W 0.94<br />

7-1 RS2 1 x 35W 0.93<br />

7-1 US2 1 x 54W 1. 00<br />

Classific<strong>at</strong>ion<br />

DIN B 6 3<br />

CIE N1: 85 N2: 99 N3: 100 N 4: 83 N 5: 73