05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

36<br />

Surface and pendant luminaires, <strong>Siteco</strong> LF2<br />

BAP60/C<strong>at</strong>.2 specular louvre<br />

Fe<strong>at</strong>ures<br />

The <strong>Siteco</strong> LF2 is an individual<br />

luminaire with minimal dimensions.<br />

Available with multiple louvre<br />

vari<strong>at</strong>ions, direct or direct/indirect<br />

distributions to suit all applic<strong>at</strong>ions in<br />

offices or administr<strong>at</strong>ion areas.<br />

4<br />

Special Fe<strong>at</strong>ures<br />

The <strong>Siteco</strong> LF2 is a luminaire with small<br />

dimensions and low profile housing<br />

only 51mm in depth. The louvre design<br />

has been optimised for the use of high<br />

efficiency T5 fluorescent tubes to<br />

achieve a high light output r<strong>at</strong>io.<br />

Housing<br />

Housing made from white finished<br />

sheet steel (similar to RAL 9010). The<br />

louvres are secured in the frame by<br />

spring c<strong>at</strong>ches. When being<br />

maintained the louvres hang on<br />

earthing safety retaining cords and are<br />

therefore still integr<strong>at</strong>ed in to the<br />

earthing safety system.<br />

Electrical<br />

The <strong>Siteco</strong> LF2 surface luminaires are<br />

wired with 3 pole terminal blocks, max.<br />

2,5mm 2 cable. The standard luminaire<br />

is fitted with high frequency control<br />

gear. During maintenance, the louver is<br />

grounded. Instabus EIB and high<br />

frequency dimming gear on request.<br />

Lighting Technology<br />

BAP60/C<strong>at</strong>.2 specular anodised<br />

aluminium louvres. L ≤ 200cd/m 2 for<br />

axial/transverse angles ≥ 60° (65° all<br />

round). On direct/indirect distribution<br />

versions approxim<strong>at</strong>ely 30% of the light<br />

is indirect. High reflectivity MIRO<br />

m<strong>at</strong>erial louvres are available on<br />

request.<br />

Recommended Applic<strong>at</strong>ions<br />

Offices or similar environments mainly<br />

equipped with VDU displays.<br />

Individual luminaire<br />

Code Lamps L W H Wt.<br />

[mm]<br />

[kg]<br />

Direct distribution<br />

HFG, T5 (high efficiency)<br />

5LF 21B 7-1M 1 x 14W 592 145 51+7 2,2<br />

5LF 21B 7-1N 1 x 21W 892 145 51+7 2,5<br />

5LF 21B 7-1P 1 x 28W 1192 145 51+7 2,9<br />

5LF 21B 7-1R 1 x 35W 1492 145 51+7 3,3<br />

5LF 21B 7-2M 2 x 14W 592 229 51+7 3,8<br />

5LF 21B 7-2N 2 x 21W 892 229 51+7 4,5<br />

5LF 21B 7-2P 2 x 28W 1192 229 51+7 5,5<br />

5LF 21B 7-2R 2 x 35W 1492 229 51+7 6,1<br />

5LF 21B 7-3M 3 x 14W 592 313 51+7 5,5<br />

HFG, T5 (high output)<br />

5LF 21B 7-1Y 1 x 24W 592 145 51+7 2,2<br />

5LF 21B 7-1K 1 x 39W 892 145 51+7 2,5<br />

5LF 21B 7-1F 1 x 49W 1492 145 51+7 3,3<br />

5LF 21B 7-1J 1 x 54W 1192 145 51+7 2,9<br />

5LF 21B 7-1X 1 x 80W 1492 145 51+7 3,3<br />

5LF 21B 7-2Y 2 x 24W 592 229 51+7 3,8<br />

5LF 21B 7-2K 2 x 39W 892 229 51+7 4,5<br />

5LF 21B 7-2F 2 x 49W 1492 229 51+7 6,1<br />

5LF 21B 7-2J 2 x 54W 1192 229 51+7 5,5<br />

5LF 21B 7-2X 2 x 80W 1492 229 51+7 6,1<br />

5LF 21B 7-3Y 3 x 24W 592 313 51+7 5,5<br />

• Continuous row luminaires on request.<br />

Individual luminaire<br />

Code Lamps L W H Wt.<br />

[mm]<br />

[kg]<br />

Direct/indirect distribution<br />

HFG, T5 (high efficiency)<br />

5LF 23B 7-1M 1 x 14W 592 145 51+7 2,2<br />

5LF 23B 7-1N 1 x 21W 892 145 51+7 2,5<br />

5LF 23B 7-1P 1 x 28W 1192 145 51+7 2,9<br />

5LF 23B 7-1R 1 x 35W 1492 145 51+7 3,3<br />

5LF 23B 7-2M 2 x 14W 592 229 51+7 3,8<br />

5LF 23B 7-2N 2 x 21W 892 229 51+7 4,5<br />

5LF 23B 7-2P 2 x 28W 1192 229 51+7 5,5<br />

5LF 23B 7-2R 2 x 35W 1492 229 51+7 6,1<br />

HFG, T5 (high output)<br />

5LF 23B 7-1Y 1 x 24W 592 145 51+7 2,2<br />

5LF 23B 7-1K 1 x 39W 892 145 51+7 2,5<br />

5LF 23B 7-1F 1 x 49W 1492 145 51+7 3,3<br />

5LF 23B 7-1J 1 x 54W 1192 145 51+7 2,9<br />

5LF 23B 7-1X 1 x 80W 1492 145 51+7 3,3<br />

5LF 23B 7-2Y 2 x 24W 592 229 51+7 3,8<br />

5LF 23B 7-2K 2 x 39W 892 229 51+7 4,5<br />

5LF 23B 7-2F 2 x 49W 1492 229 51+7 6,1<br />

5LF 23B 7-2J 2 x 54W 1192 229 51+7 5,5<br />

5LF 23B 7-2X 2 x 80W 1492 229 51+7 6,1