High bay reflector luminaire, ASTER<br />

13<br />

with wide beam aluminium facetted reflector<br />

Facet detail Eyebolt detail Cover glass for ingress<br />

protection IP 44<br />

Accessories<br />

Housing<br />

Code<br />

Cover glass<br />

5NJ 910 0-0XG<br />

Install<strong>at</strong>ion<br />

Code<br />

Chain, galvanised 5LY 905 5<br />

Quick-release link,<br />

galvanised 5LY 911 3<br />

Stainless steel chain 5LY 911 1<br />

•Detailed description see page 10/18.<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Emergency conversion<br />

components 10/22<br />

Refurbishment<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

10<br />

Luminaire : 5NJ 851 2-1 E with 1 x HME 250W ( Lumen output : 1 x 1 3000 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 79%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 p = 1.25<br />

Magnetic<br />

En [lx] 100 200 300 500<br />

Lh [m] 10 12 10 12 10 12 10 12<br />

500 9.1 10 18 21 27 31 46 51<br />

75 0 12 14 24 27 37 41 61 68<br />

10 00 15 17 31 34 46 50 77 84<br />

12 50 18 20 37 40 55 60 91 99<br />

15 00 21 23 42 46 64 69 106 115<br />

17 50 24 26 48 52 72 78 121 130<br />

2000 27 29 54 58 81 86 135 144<br />

25 00 33 35 66 69 99 104 165 174<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 32 24 31 24 29 23 23 17<br />

0.80 42 32 40 33 37 31 31 25<br />

1.00 51 40 48 41 45 39 39 33<br />

1.25 58 47 54 48 51 45 45 39<br />

1.50 64 53 60 54 56 51 50 45<br />

2.00 73 60 67 62 63 59 58 53<br />

3.00 81 67 74 70 69 66 64 60<br />

5.00 90 74 81 78 74 72 71 67<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

Magnetic<br />

1 x 2 50W 267<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.45<br />

ϕ so 0.00<br />

Conversion factor F1 for 5NJ 851 .-..<br />

Magnetic<br />

Conversion factor F for 5NJ 851 .-..<br />

Magnetic<br />

Classific<strong>at</strong>ion<br />

DIN A 3 0<br />

CIE N1: 37 N 2: 79 N3: 98 N4: 100 N 5: 79<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT