05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Recessed downlights for compact fluorescent lamps Lunis®<br />

23<br />

Extreme wide beam<br />

2<br />

Gearbox can be suspended in<br />

the ceiling void<br />

Detail of standard switchstart<br />

gearbox unit<br />

With Turbo louvre<br />

With Cross baffle<br />

Accessories<br />

Optical<br />

Code<br />

Accessory cross 5LR 941 6-1AD<br />

louvre BAP60/C<strong>at</strong>.2<br />

Accessory turbo 5LR 941 6-1AA<br />

louvre BAP60/C<strong>at</strong>.2<br />

Accessory suspended glass<br />

Inner frosted finish 5LR 951 6-3EJ<br />

Outer frosted finish 5LR 951 6-3EK<br />

Totally frosted finish 5LR 951 6-3EL<br />

Accessory cover glass IP44<br />

Inner frosted finish 5LR 951 6-3EB<br />

Outer frosted finish 5LR 951 6-3EF<br />

Totally frosted finish 5LR 951 6-3EE<br />

Clear<br />

5LR 951 6-3EA<br />

Accessory cover glass IP54<br />

Inner frosted finish 5LR 951 6-3ED<br />

Outer frosted finish 5LR 951 6-3EH<br />

Totally frosted finish 5LR 951 6-3EG<br />

Clear<br />

5LR 951 6-3EC<br />

Housing<br />

Code<br />

Decor<strong>at</strong>ive silicon<br />

bezel white<br />

5LR 951 6-4GP<br />

bezel blue<br />

5LR 951 6-6GP<br />

• Notes<br />

Luminaires exceeding a w<strong>at</strong>tage<br />

totalling more than 36W should not<br />

have any cover glasses due to<br />

thermal consider<strong>at</strong>ions.<br />

Electrical<br />

Code<br />

2 pole additional 5LJ 800 0-2XK<br />

terminal block<br />

Cable<br />

5LJ 800 0-2XW<br />

strain relief<br />

3 hour emergency 5LJ 415 x-xxx 61-03<br />

conversion 1)<br />

1 hour emergency 5LJ 415 x-xxx 61-02<br />

conversion 1)<br />

E14 emergency 5LR 415 x-xxx 61-01<br />

lampholder 1)<br />

Mounting<br />

Code<br />

Concrete<br />

5LR 911 6-0BD<br />

casting box<br />

Panel ceiling pl<strong>at</strong>e 5LR 911 6-4BG<br />

Plastered aperture 5LR 911 6-0BC<br />

ceiling ring<br />

Cut aperture<br />

5LR 911 6-0BF<br />

ceiling ring<br />

Backing pl<strong>at</strong>e<br />

5LR 911 6-0BA<br />

1)Please note the specific<strong>at</strong>ions for the<br />

emergency unit on page 2/48.<br />

• Please specify the order number of<br />

the emergency unit with the<br />

relevant downlighter.<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Power factor correction<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

Luminaire : 5LR 114 7-1LA61 with 1 x TC-TEL 26W and HFG ( Lumen output : 1 x 1800 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 69%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 200 300 500<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 2.3 2.5 4.6 5.1 7. 0 7. 6 12 13<br />

30 3. 3 3. 6 6.5 7. 1 9.8 11 16 18<br />

40 4.2 4.5 8.4 9.0 13 14 21 23<br />

50 5.1 5.4 10 11 15 16 25 27<br />

75 7. 4 7. 7 15 15 22 23 37 39<br />

100 9.8 10 20 20 29 30 49 50<br />

200 19 19 37 39 56 58 94 97<br />

500 46 47 93 93 139 140 231 233<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 39 33 38 33 36 32 32 28<br />

0.80 49 41 47 42 45 41 40 37<br />

1.00 57 50 55 50 52 49 48 45<br />

1.25 62 54 59 55 56 53 52 49<br />

1.50 67 58 63 59 59 57 56 53<br />

2.00 73 63 68 65 63 61 61 58<br />

3.00 78 66 71 69 66 65 64 61<br />

5.00 82 69 75 73 69 68 66 64<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 2 6W 28<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.67<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LR 114 .-..<br />

HFG<br />

Conversion factor F for 5LR 114 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1: 75 N 2: 99 N3: 100 N 4: 100 N 5: 69<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT