12 Appendix<br />

Control gear<br />

appendix<br />

Electronic control gear (HFG) for fluorescent lamps<br />

More efficient working through high frequency lighting<br />

Apart from the economical and ecological points of view, there<br />

are also more very positive consequences of high frequency light<br />

to the working person. New research in the area of ergonomics<br />

verifies the studies of the engineering office of Christian<br />

Bartenbach, Innsbruck, Austria. Flicker is a serious problem factor<br />

in visual comfort. This is made worse when working in a VDU<br />

area. The consequences are f<strong>at</strong>igue, lack of concentr<strong>at</strong>ion and<br />

more mistakes. Using fluorescent lamps and HF gear it is possible<br />

to work without flicker in contrast to conventionally oper<strong>at</strong>ed<br />

lamps. This leads to many proven advantages and generally more<br />

comfortable work places.<br />

Comfort<br />

• Instant start<br />

• Pleasant, flicker-free light without stroboscopic effects due to<br />

high frequency oper<strong>at</strong>ion<br />

• High visual comfort without disruptive low-frequency noises<br />

• No flashing and flickering, defective lamps are switched off by<br />

the electronic fault supervision circuit<br />

Safety<br />

• Safety switch off of current supply to defective lamp<br />

• Over voltage protection switching for short term voltage<br />

impulses (corresponding to DIN VDE 160 standards) and for<br />

temporary over voltage<br />

• Possibility of using in emergency lighting equipment according<br />

to DIN VDE 0108.<br />

Life expectancy and reliability of electronic control gear<br />

The failure r<strong>at</strong>e of electronic components depends on the build<br />

quality of the units and the ambient temper<strong>at</strong>ure. The OSRAM<br />

electronic control gear units are designed in such a way so th<strong>at</strong><br />

under the maximum permitted oper<strong>at</strong>ing temper<strong>at</strong>ure (tc<br />

max=70°C), a failure r<strong>at</strong>e is expected of less than 0,2% per 1000<br />

oper<strong>at</strong>ing hours. This corresponds to an expected life time of<br />

50000h <strong>at</strong> a failure percentage of less than 10%. If the oper<strong>at</strong>ing<br />

temper<strong>at</strong>ure is reduced by 10 degrees the failure r<strong>at</strong>e can further<br />

be reduced by a factor of 2.<br />

HFG life expectancy – calcul<strong>at</strong>ed values<br />

100%<br />

80%<br />

60%<br />

Oper<strong>at</strong>ing units HFG<br />

50¡C<br />

HFG for T8 lamps<br />

Economy<br />

• 27% lower power consumption<br />

• 50% longer lamp life, leading to lower maintenance costs,<br />

fewer lamp and ballast changes required<br />

• Lower load for the air-conditioning through lower he<strong>at</strong> build<br />

up within the luminaires<br />

100%<br />

90%<br />

80%<br />

70%<br />

60%<br />

50%<br />

0<br />

Rel<strong>at</strong>ive light output<br />

Life expectancy<br />

HFG for T5 lamps<br />

Switchstart/low-loss<br />

2.000 4.000 6.0008.000 10.000 12.000 14.000 16.000 18.000 20.000 22.000 24.000 (h)<br />

Burning hours<br />

Increased lamp life expectancy (<strong>at</strong> 80% still oper<strong>at</strong>ing)<br />

from 10000 hours <strong>at</strong> IEC-3 standard oper<strong>at</strong>ing cycle<br />

(165 min. on / 15 min. off)<br />

HFG<br />

The T5 lamps herald a new gener<strong>at</strong>ion of modern lighting<br />

systems. They are distinguished by their smaller lamp diameters<br />

(d=16mm) and slim ballasts. The oper<strong>at</strong>ion of T5 lamps is only<br />

possible with electronic control gear.<br />

Two product ranges<br />

1. T5, high efficiency (HE), optimised for max. light efficacy (up to<br />

104lm/W), in w<strong>at</strong>tages 14W, 21W, 28W and 35W<br />

2. T5, high output (HO), optimised for max. light output (up to<br />

7000lm for 80W), in w<strong>at</strong>tages 24W, 39W, 49W and 80W.<br />

Economy<br />

• Very high system efficacy from T5 high efficiency (HE), in<br />

particular through »Cut Off technology«<br />

• High lumen package from T5 high output (HO)<br />

• High lamp life expectancy through gentle lamp oper<strong>at</strong>ing with<br />

»Cut Off technology«<br />

• Low maintenance costs through high lamp life expectancy and<br />

reduced relamping intervals<br />

• Lower load for the air-conditioning through lower he<strong>at</strong> build<br />

up within the luminaires<br />

40%<br />

20%<br />

90 C<br />

70¡C<br />

60¡C<br />

0<br />

0 20 40 60 80 100 120 140<br />

Working hours x 1000