Refurbishment luminaire, <strong>Siteco</strong> LF7<br />

13<br />

Crossblade louvre<br />

Luminaire mounted in<br />

existing fitting carcass<br />

Twin lamp <strong>Siteco</strong> LF7<br />

Crossblade louvre<br />

<strong>Siteco</strong> LF7 luminaire body<br />

Accessories<br />

Mounting<br />

Code<br />

Support brackets for ceiling mounting<br />

1 lamp 5LF 910 1-1<br />

2 lamp 5LF 910 1-2<br />

3 lamp 5LF 910 1-3<br />

• Detailed description see page 5/16<br />

• Dimensions see page 5/17<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Emergency conversion<br />

components 10/22<br />

Air handling<br />

appendix<br />

Refurbishment<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

5<br />

Luminaire : 5LF 726 7-1 R with 1 x 35W and HFG ( Lumen output : 1 x 3290 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 67%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 1. 3 1. 5 4.0 4.4 6.7 7. 3 10 11<br />

30 1. 9 2.0 5.6 6.1 9.3 10 14 15<br />

40 2.4 2.6 7. 2 7. 8 12 13 18 19<br />

50 2.9 3. 1 8.7 9.4 15 16 22 23<br />

75 4.2 4.4 13 13 21 22 32 33<br />

100 5.6 5.7 17 17 28 29 42 43<br />

200 11 11 32 33 54 55 81 83<br />

500 27 27 80 80 133 134 200 201<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρ<br />

ρ<br />

ρ<br />

Room Index k<br />

B<br />

Ceiling 80 80 70 70 50 50 30 0<br />

Wall 50 30 50 30 50 30 30 0<br />

Floor 30 10 20 20 10 10 10 0<br />

0.60 37 31 36 31 34 30 30 26<br />

0.80 46 39 44 39 42 38 38 34<br />

1.00 54 47 52 47 49 46 45 42<br />

1.25 59 51 56 52 53 50 49 46<br />

1.50 64 55 60 56 56 54 53 50<br />

2.00 70 60 65 62 61 59 58 55<br />

3.00 74 63 68 66 63 62 61 58<br />

5.00 78 66 71 69 65 64 63 60<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 35W 38<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.66<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LF 726 .-..<br />

HFG<br />

Conversion factor F for 5LF 726 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1: 71 N 2: 98 N3: 100 N 4: 100 N 5: 67<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT