Surface and pendant luminaires, <strong>Siteco</strong> LF2<br />

37<br />

BAP60/C<strong>at</strong>.2 specular louvre<br />

Direct/indirect distribution. Special colour luminaire Size comparison: <strong>Siteco</strong> LF2 (T5) with <strong>Siteco</strong> LP2 (T8).<br />

4<br />

Accessories<br />

Electrical<br />

Code<br />

Through wiring for 28W/54W<br />

3 x 1,5mm 2 5LY 911 5<br />

5 x 1,5mm 2 5LY 911 7<br />

Through wiring for 35W/49W/80W<br />

3 x 1,5mm 2 5LY 911 6<br />

5 x 1,5mm 2 5LY 911 8<br />

Additional terminal block<br />

2 pole (L2, L3) 5LJ 800 0-2XK<br />

3 pole (L1, N, E) 5LJ 800 0-3XK<br />

Mounting<br />

Code<br />

Twin wire suspension – 1000mm<br />

Single lamp<br />

Without terminal block 5LF 913 0-1<br />

With 5 pole<br />

terminal block 5LF 913 1-1<br />

Twin lamp<br />

Without terminal block 5LF 914 0-1<br />

With 5 pole<br />

terminal block 5LF 914 1-2<br />

Luminaire joint bracket 5LL 920 0-2<br />

• Detailed description see page 4/46<br />

• Dimensions see page 4/48.<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Luminaire : 5LF 21 B 7-1 R with 1 x 35W and HFG ( Lumen output : 1 x 3290 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 64%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 1. 4 1. 5 4.2 4.5 6.9 7. 6 10 11<br />

30 1. 9 2.1 5.8 6.4 9.7 11 15 16<br />

40 2.5 2.7 7. 5 8.1 12 13 19 20<br />

50 3. 0 3. 3 9.1 9.8 15 16 23 24<br />

75 4.4 4.6 13 14 22 23 33 35<br />

100 5.9 6.0 18 18 29 30 44 45<br />

200 11 12 34 35 56 58 84 87<br />

500 28 28 83 84 138 139 208 209<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 36 30 35 30 33 30 29 26<br />

0.80 45 38 43 38 41 37 37 33<br />

1.00 53 45 50 46 48 45 44 41<br />

1.25 57 49 54 50 51 48 48 44<br />

1.50 61 53 57 54 54 52 51 48<br />

2.00 67 57 62 59 58 56 56 53<br />

3.00 71 60 65 62 60 59 58 55<br />

5.00 75 63 68 66 63 62 60 58<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 35W 38<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.67<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LF 21 B .-..<br />

HFG<br />

Conversion factor F for 5LF 21 B .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1: 75 N 2: 100 N 3: 100 N 4: 100 N 5: 64<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT