Recessed downlights for premium install<strong>at</strong>ions Lunis_E<br />

17<br />

Wallwasher, narrow beam<br />

2<br />

Gearbox can be suspended in<br />

the ceiling void<br />

With white decor<strong>at</strong>ive bezel<br />

With brushed aluminium<br />

decor<strong>at</strong>ive bezel<br />

Example of a typical applic<strong>at</strong>ion<br />

Accessories<br />

Optical<br />

Code<br />

Cover glass with<br />

white decor<strong>at</strong>ive bezel<br />

Clear<br />

5LR 954 6-4EA<br />

Cover glass with<br />

anodised decor<strong>at</strong>ive bezel<br />

Clear<br />

5LR 954 6-7EB<br />

Housing<br />

Code<br />

Aluminium decor<strong>at</strong>ive bezel<br />

White finished 5LR 954 6-4AP<br />

Brushed and anodised 5LR 954 6-7AP<br />

• Notes<br />

Luminaires exceeding a w<strong>at</strong>tage<br />

totalling more than 36W should not<br />

have any cover glasses due to<br />

thermal consider<strong>at</strong>ions.<br />

Electrical<br />

Code<br />

2 pole additional 5LJ 800 0-2XK<br />

terminal block<br />

Cable<br />

5LJ 800 0-2XW<br />

strain relief<br />

3 hour emergency 5LJ 411 x-xxx 61-03<br />

conversion 1)<br />

1 hour emergency 5LJ 411 x-xxx 61-02<br />

conversion 1)<br />

Mounting<br />

Code<br />

Concrete<br />

casting box<br />

on request<br />

Panel ceiling pl<strong>at</strong>e 5LR 911 6-4BG<br />

Plastered aperture 5LR 911 6-0BC<br />

ceiling ring<br />

Cut aperture<br />

5LR 911 6-0BF<br />

ceiling ring<br />

Backing pl<strong>at</strong>e<br />

5LR 911 6-0BA<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Power factor correction<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

1)Please note the specific<strong>at</strong>ions for the<br />

emergency unit on page 2/48.<br />

• Please specify the order number of<br />

the emergency unit with the relevant<br />

downlighter.<br />

Luminaire: 5LR 415 7-1MA61 with 1 xTC-TEL 32W and HFG (Lumen output: 1 x 2400 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

Isolux curves<br />

C0 - 1 80 C90 - 27 0<br />

Total light output r<strong>at</strong>io (LOR) = 68%<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.73<br />

ϕ so 0.00<br />

Wall dimensions<br />

Width<br />

3 ,00 m<br />

Height<br />

3 ,00 m<br />

Distance to Luminaire<br />

A<br />

0,50 m<br />

B<br />

1 ,00 m<br />

Legend ( A )<br />

1 60 lx<br />

80 lx<br />

40 lx<br />

Legend ( B )<br />

80 lx<br />

60 lx<br />

40 lx<br />

Maint. Factor 0,8<br />

A<br />

B