High bay reflector luminaire, HS 100<br />

27<br />

With special high-rack reflector<br />

90<br />

60<br />

30<br />

180<br />

0<br />

210<br />

240<br />

270<br />

Plug and socket connection Two point suspension Front view with light distribution angle inform<strong>at</strong>ion<br />

Accessories<br />

Install<strong>at</strong>ion<br />

Code<br />

Chain, galvanised 5LY 905 5<br />

Quick-release link,<br />

galvanised 5LY 911 3<br />

Stainless steel chain 5LY 911 1<br />

• Detailed description see page 10/18.<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Control gear<br />

Power factor correction<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

a<br />

h<br />

w<br />

Vertical illuminance<br />

Horizontal illuminance<br />

a=4m, w=2,5m, h=5,5m<br />

a=5m, w=2,5m, h=7,5m<br />

Height Ev (Lux) Height Ev (Lux)<br />

above Measured on shelf face above Measured on shelf face<br />

floor HQL 250W HQL 400W floor HQL 250W HQL 400W<br />

[m] 1) 2) 1) 2) [m] 1) 2) 1) 2)<br />

4,5 660 330 920 460 6,5 620 200 820 270<br />

4,0 400 270 570 370 6,0 370 170 510 230<br />

3,5 270 210 370 300 5,5 230 140 320 200<br />

3,0 190 170 270 240 5,0 160 120 220 170<br />

2,5 150 140 210 200 4,5 120 100 160 140<br />

2,0 120 120 170 160 4,0 90 90 130 120<br />

1,5 100 100 140 140 3,5 80 80 110 100<br />

1,0 85 85 120 120 3,0 70 70 90 90<br />

2,5 60 60 80 80<br />

2,0 50 50 70 70<br />

Eh (Lux) measured above floor<br />

1m 185 255 1m 105 150<br />