Recessed downlights for compact fluorescent lamps Lunis®<br />

31<br />

Narrow beam<br />

2<br />

Gearbox can be suspended in<br />

the ceiling void<br />

With decor<strong>at</strong>ive silicon bezel,<br />

blue<br />

Suspended glass, outer frosted<br />

finish<br />

Accessories<br />

Optical<br />

Code<br />

Electrical<br />

Code<br />

Accessory suspended glass<br />

2 pole additional 5LJ 800 0-2XK<br />

Inner frosted finish 5LR 951 5-3EJ terminal block<br />

Outer frosted finish 5LR 951 5-3EK Cable<br />

5LJ 800 0-2XW<br />

Totally frosted finish 5LR 951 5-3EJ strain relief<br />

Accessory cover glass IP44<br />

3 hour emergency 5LR 111 x-xxx 51-03<br />

Inner frosted finish 5LR 951 5-3EB conversion 1)<br />

Outer frosted finish 5LR 951 5-3EF 1 hour emergency 5LR 111 x-xxx 51-01<br />

Totally frosted finish 5LR 951 5-3EE conversion 1)<br />

Clear<br />

5LR 951 5-3EA<br />

Mounting<br />

Code<br />

Accessory cover glass IP54<br />

Concrete<br />

on request<br />

Inner frosted finish 5LR 951 5-3ED<br />

casting box<br />

Outer frosted finish 5LR 951 5-3EH<br />

Panel ceiling pl<strong>at</strong>e 5LR 911 5-4 BG<br />

Totally frosted finish 5LR 951 5-3EG<br />

Plastered aperture 5LR 911 5-0 BC<br />

Clear<br />

5LR 951 5-3EC<br />

ceiling ring<br />

Housing<br />

Code<br />

Cut aperture<br />

5LR 911 5-0 BF<br />

Decor<strong>at</strong>ive silicon bezel<br />

white<br />

5LR 951 5-4GP<br />

ceiling ring<br />

Backing pl<strong>at</strong>e<br />

5LR 911 5-0 BA<br />

blue<br />

5LR 951 5-6GP<br />

• Notes<br />

Luminaires exceeding a w<strong>at</strong>tage 1)Please note the specific<strong>at</strong>ions for the<br />

totalling more than 36W should not emergency unit on page 2/48.<br />

have any cover glasses due to thermal • Please specify the order number of<br />

consider<strong>at</strong>ions.<br />

the emergency unit with the relevant<br />

downlighter.<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Power factor correction<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

Luminaire : 5LR 111 7-1FA51 with 1 xTC-DEL 13W and HFG ( Lumen output : 1 x 900 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

H [m] Ø [m] E [lx]<br />

1 0.88 440<br />

2 1. 76 110<br />

3 2.63 50<br />

Beam angle : 47°<br />

Total light output r<strong>at</strong>io (LOR) = 60%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 200 300 500<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 5.1 5.6 10 11 15 17 26 28<br />

30 7. 2 7. 8 14 16 22 23 36 39<br />

40 9.3 9.9 19 20 28 30 47 50<br />

50 11 12 23 24 34 36 57 60<br />

75 17 17 33 34 50 52 83 86<br />

100 22 22 44 45 66 67 110 112<br />

200 43 44 86 88 129 131 215 219<br />

500 106 107 212 213 318 320 530 533<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 38 32 36 32 35 32 31 28<br />

0.80 45 39 43 40 41 39 38 35<br />

1.00 52 46 50 46 47 45 45 42<br />

1.25 57 49 53 50 51 48 48 46<br />

1.50 60 53 57 54 54 52 51 49<br />

2.00 65 57 61 59 57 56 55 53<br />

3.00 69 59 63 62 59 58 57 55<br />

5.00 72 61 65 64 60 59 58 56<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 1 3W 16<br />

Light distribution to DIN 5040<br />

Conversion factor F1 for 5LR 111 .-..<br />

Conversion factor F for 5LR 111 .-..<br />

Classific<strong>at</strong>ion<br />

ϕ u 1. 00<br />

ϕ su 0.75<br />

ϕ so 0.00<br />

HFG<br />

HFG<br />

DIN A 6 0<br />

CIE N1: 77 N 2: 99 N3: 100 N 4: 100 N 5: 60<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT