Surface luminaire, Ceilingwasher<br />

99<br />

Asymmetric ceiling or wall washer, m<strong>at</strong>t reflector<br />

Wallwashing orient<strong>at</strong>ion<br />

Reflector detail<br />

Control gear and terminal<br />

block detail<br />

4<br />

Accessories<br />

Electrical<br />

Code<br />

Through wiring for 36W<br />

3 x 1,5mm 2 5LY 911 5<br />

5 x 1,5mm 2 5LY 911 7<br />

Through wiring for 58W<br />

3 x 1,5mm 2 5LY 911 6<br />

5 x 1,5mm 2 5LY 911 8<br />

Additional terminal<br />

block (L2,L3) 5LY 918 0<br />

• Detailed description on page 4/100<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Emergency conversion<br />

components 10/22<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Luminaire : 5LM 701 7-1 E with 1 x 58W and HFG ( Lumen output : 1 x 5000 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 71%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20<br />

30<br />

40<br />

50<br />

75<br />

100<br />

200<br />

500<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60<br />

0.80<br />

1.00<br />

1.25<br />

1.50<br />

2.00<br />

3.00<br />

5.00<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 36W 34<br />

1 x 58W 53<br />

Light distribution to DIN 5040<br />

ϕ u 0.00<br />

ϕ su 0.00<br />

ϕ so 0.49<br />

Conversion factor F1 for 5LM 701 .-..<br />

HFG<br />

Conversion factor F for 5LM 701 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN E 0 1<br />

CIE N1: 0 N2: 0 N3: 11 N 4: 1 N 5: 71<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT