B<strong>at</strong>ten luminaires for T5 and T8 lamps<br />

57<br />

with open lamp distribution<br />

Suspended T5 b<strong>at</strong>ten T8 b<strong>at</strong>ten Twin lamp T5 b<strong>at</strong>ten Suspended twin lamp T8 b<strong>at</strong>ten<br />

Accessories<br />

Electrical<br />

Through wiring block<br />

5 x 2,5mm 2<br />

Mounting<br />

Suspension clip<br />

Code<br />

5LJ 100 2-1EK<br />

Code<br />

5LJ 100 1-0XC<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Refurbishment<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

7<br />

Luminaire : 5LJ 100 7-1 E with 1 x 58W and HFG ( Lumen output : 1 x 5000 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 88%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 0.9 1. 0 2.6 3. 1 4.3 5.2 6.5 7. 7<br />

30 1. 2 1. 4 3. 6 4.2 6.0 7. 0 9.0 10<br />

40 1. 5 1. 7 4.6 5.2 7. 6 8.7 11 13<br />

50 1. 9 2.1 5.6 6.2 9.3 10 14 16<br />

75 2.6 2.9 7. 9 8.7 13 15 20 22<br />

100 3. 4 3. 7 10 11 17 19 26 28<br />

200 6.6 6.8 20 20 33 34 50 51<br />

500 16 16 49 49 81 82 122 124<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 30 20 28 20 26 19 18 11<br />

0.80 38 27 35 27 32 25 24 16<br />

1.00 45 33 42 33 38 31 29 21<br />

1.25 51 38 47 38 42 35 33 25<br />

1.50 57 43 52 43 46 39 37 28<br />

2.00 66 51 59 51 52 46 43 34<br />

3.00 75 59 67 60 59 53 50 40<br />

5.00 85 68 75 69 65 61 56 46<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 5 8W 53<br />

Light distribution to DIN 5040<br />

ϕ u 0.73<br />

ϕ su 0.43<br />

ϕ so 0.23<br />

Conversion factor F1 for 5LJ 100 .-..<br />

HFG<br />

Conversion factor F for 5LJ 100 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN B 3 1<br />

CIE N1: 31 N 2: 59 N3: 82 N4: 73 N 5: 88<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT