05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

36 Floodlights, SiCOMPACT A MIDI<br />

Asymmetric floodlight<br />

Fe<strong>at</strong>ures<br />

Asymmetric distribution floodlight<br />

with modern design for area lighting<br />

with minimal light spill.<br />

Special Fe<strong>at</strong>ures<br />

IP 65 protection. The luminaire has<br />

been tested in accordance with DIN<br />

VDE 0710 Part 13 for use in<br />

environments where ball impact<br />

resistance is required. Wide and<br />

narrow distribution reflector optics<br />

available: adjustment through 360°<br />

any oper<strong>at</strong>ing environment up to<br />

ambient temper<strong>at</strong>ure of 35°C.<br />

10<br />

Housing<br />

Two part corrosion resistant pressure<br />

die-cast aluminium housing, semim<strong>at</strong>t<br />

powder co<strong>at</strong> in standard colour<br />

light grey (RAL 7035). Further RAL<br />

colours available on request. Fl<strong>at</strong><br />

temper<strong>at</strong>ure resistant cover glass.<br />

Housing divided into lamp<br />

compartment and control gear<br />

section (temper<strong>at</strong>ure barrier for<br />

electronic gear protection). Drain<br />

aperture to prevent condens<strong>at</strong>ion<br />

build-up. Support bracket: steel,<br />

galvanised and powder co<strong>at</strong>ed.<br />

Electrical<br />

Asymmetric floodlights are wired<br />

and fitted with standard 3 pole<br />

terminal block, max. 2,5mm 2 cable.<br />

Floodlight with integral ignitor and<br />

control gear, power factor corrected.<br />

Hot restrike version available with<br />

autom<strong>at</strong>ic mains disconnection on<br />

opening the casing. Emergency lamp<br />

holder on request.<br />

Code Lamps Wt.<br />

[kg]<br />

Narrow beam<br />

Magnetic ballast, normal ignitor<br />

5NA 748 2-1SB0 1 x HIT / HST 250W 16,9<br />

5NA 748 2-1RB02 1 x HIT-DE 250W 16,9<br />

5NA 748 2-1SB02 1 x HST-DE 250W 16,9<br />

5NA 748 2-1TB0 1 x HIT / HST 400W 18,4<br />

5NA 748 2-1TB02 1 x HIT-DE / HST-DE 400W 18,4<br />

Magnetic ballast, hot restrike ignitor<br />

5NA 748 6-1RB02 1 x HIT-DE 250W 19,9<br />

5NA 748 6-1SB02 1 x HST-DE 250W 19,9<br />

5NA 748 6-1TB02 1 x HIT-DE / HST-DE 400W 21,4<br />

• Dimensions see page 10/42<br />

Code Lamps Wt.<br />

[kg]<br />

Magnetic ballast, normal ignitor<br />

5NA 748 2-1SS0 1 x HIT / HST 250W 16,9<br />

5NA 748 2-1RS02 1 x HIT-DE 250W 16,9<br />

5NA 748 2-1SS02 1 x HST-DE 250W 16,9<br />

5NA 748 2-1TS0 1 x HIT / HST 400W 18,4<br />

5NA 748 2-1TS02 1 x HIT-DE / HST-DE 400W 18,4<br />

Magnetic ballast, hot restrike ignitor<br />

5NA 748 6-1RS02 1 x HIT-DE 250W 19,9<br />

5NA 748 6-1SS02 1 x HST-DE 250W 19,9<br />

5NA 748 6-1TS02 1 x HIT-DE / HST-DE 400W 21,4<br />

Lighting Technology<br />

Asymmetric specular reflector with<br />

peak output <strong>at</strong> 45° (Imax), with wide<br />

or narrow distribution. Due to<br />

extensive angle adjustment, also<br />

suitable as up-light or wall light.<br />

Recommended Applic<strong>at</strong>ions<br />

Sports facilities, tennis halls, outdoor<br />

sports arenas.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!