Surface diffuser luminaire, Europlex TC<br />

11<br />

with stylish opal diffuser<br />

Round luminaire, IP54 or IP65 Cable entry and terminal block Round luminaire body Cable entry and terminal block<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Refurbishment<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

• Dimensions see page 8/15<br />

Square luminaire body<br />

8<br />

Luminaire : 5LS 234 1-6 SR with 1 x TC-S 9W and Switchstart ( Lumen output : 1 x 600 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 44%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

Switchstart<br />

En [lx] 100 200 300 500<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 13 15 25 29 38 44 63 73<br />

30 18 20 35 40 53 60 88 100<br />

40 22 25 45 51 67 76 112 127<br />

50 27 30 55 61 82 91 137 152<br />

75 39 42 78 85 117 127 194 212<br />

100 51 55 102 110 153 165 254 275<br />

150 76 78 151 156 227 234 378 390<br />

200 100 102 201 204 301 305 501 509<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 18 13 17 14 16 13 13 10<br />

0.80 23 17 21 17 20 17 16 13<br />

1.00 27 21 25 21 23 20 20 16<br />

1.25 30 24 28 24 26 23 22 19<br />

1.50 33 27 31 27 28 25 25 21<br />

2.00 37 30 34 31 31 29 28 24<br />

3.00 42 35 38 36 35 33 31 28<br />

5.00 47 38 42 40 37 36 34 31<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

Switchstart<br />

1 x 9 W 15<br />

Light distribution to DIN 5040<br />

ϕ u 0.89<br />

ϕ su 0.50<br />

ϕ so 0.29<br />

Conversion factor F1 for 5LS 234 .-..<br />

Switchstart<br />

Conversion factor F for 5LS 234 .-..<br />

Switchstart<br />

Classific<strong>at</strong>ion<br />

DIN B 3 1<br />

CIE N1: 41 N 2: 71 N 3: 90 N4: 89 N5: 44<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT