05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Pendant luminaires, SiFORM for individual and continuous mounting<br />

27<br />

SECONDARY-Modul II<br />

Luminaire module end<br />

detail.<br />

Luminaire module for<br />

continuous mounting.<br />

MUF detail showing droprod<br />

fixings<br />

4<br />

Accessories<br />

Mounting<br />

Code<br />

Multifunction rail 5LM 100 0-1<br />

Cover for MUF<br />

1,19m 5LM 100 0-4<br />

3,00m 5LM 100 0-2<br />

End caps for MUF 5LM 100 0-3<br />

• System overview see page 4/12.<br />

• Detailed description see page 4/13.<br />

• Dimensions see page 4/32.<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Refurbishment<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Individual SECONDARY Module II luminaire<br />

Luminaire : 5LM 17 6 7-1 RS3 with 1 x 35W and HFG ( Lumen output : 1 x 3290 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 180 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 66%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1.7 1.9 5.2 5.8 8.6 9.6 13 14<br />

30 2.4 2.7 7.2 8.0 12 13 18 20<br />

40 3.1 3.3 9.2 10 15 17 23 25<br />

50 3.7 4.0 11 12 19 20 28 30<br />

75 5.3 5.7 16 17 26 28 40 43<br />

100 6.6 7.3 20 22 33 36 50 55<br />

200 12 13 37 39 61 65 92 97<br />

500 29 30 88 89 147 148 221 222<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 34 27 32 27 31 27 26 22<br />

0.80 38 31 37 31 35 30 30 25<br />

1.00 43 34 40 35 38 33 33 28<br />

1.25 47 38 44 38 41 37 36 31<br />

1.50 51 41 47 42 44 40 39 34<br />

2.00 56 45 52 46 48 44 43 38<br />

3.00 65 53 59 55 54 51 50 46<br />

5.00 72 60 65 62 60 58 57 53<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 28W 31<br />

1 x 35W 38<br />

Light distribution to DIN 5040<br />

ϕ u 1.00<br />

ϕ su 0.58<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LM 17 6 .-..<br />

HFG<br />

7-1PS3 1 x 28W 1.24<br />

7-1RS3 1 x 35W 1.00<br />

Conversion factor F for 5LM 17 6 .-..<br />

HFG<br />

7-1PS3 1 x 28W 1.02<br />

7-1RS3 1 x 35W 1.00<br />

Classific<strong>at</strong>ion<br />

DIN A 4 0<br />

CIE N1: 55 N2: 86 N3: 98 N4: 100 N5: 66<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT