Siluna VT – recessed luminaire with “visual depth effect”<br />

29<br />

with BAP60/C<strong>at</strong>.2 louvre<br />

Stereotypical office and<br />

ceiling areas, often lit by<br />

conventional louvre<br />

luminaires will be livened up<br />

by the visual depth effect.<br />

Reduced contrast within the<br />

luminaires gives rise to more<br />

pleasant lighting.<br />

The use of a specially co<strong>at</strong>ed<br />

and partially coloured<br />

reflector surface in the<br />

canopy area cre<strong>at</strong>es a defined<br />

interplay between colour<br />

effects and white light. The<br />

colour effects are changeable<br />

and could be used to support<br />

a uniform building or<br />

corpor<strong>at</strong>e identity concept.<br />

Detail with blue baffle<br />

Design concept<br />

Kurt-G. Müggenburg<br />

Aluminium end cap detail<br />

Product detail<br />

Accessories<br />

Optical<br />

Code<br />

Colour baffles<br />

Green<br />

Blue<br />

Yellow<br />

5LY 915 87KU16<br />

5LY 915 87KU17<br />

5LY 915 87KU18<br />

L<br />

32<br />

H<br />

• These are custom made<br />

products with prices and<br />

availability confirmed upon<br />

request.<br />

87,5<br />

w<br />

35<br />

11<br />

Luminaire : 5LK 400 87KU15 with 1 x 39W and HFG ( Lumen output : 1 x 3080 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 27 0<br />

Total light output r<strong>at</strong>io (LOR) = 70%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1. 3 1. 5 4.0 4.4 6.7 7. 3 10 11<br />

30 1. 9 2.1 5.7 6.2 9.5 10 14 15<br />

40 2.4 2.6 7. 3 7. 8 12 13 18 20<br />

50 3. 0 3. 2 8.9 9.5 15 16 22 24<br />

75 4.3 4.5 13 14 21 23 32 34<br />

100 5.7 5.8 17 17 28 29 43 44<br />

200 11 11 33 34 54 56 82 84<br />

500 27 27 81 81 13 4 13 5 202 203<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 41 35 40 35 38 34 34 30<br />

0.80 50 43 48 43 46 42 42 38<br />

1.00 59 51 56 52 53 50 49 46<br />

1.25 63 54 60 56 56 53 53 49<br />

1.50 67 58 63 59 59 57 56 53<br />

2.00 73 63 68 65 64 62 61 58<br />

3.00 78 66 72 69 66 65 64 61<br />

5.00 83 70 75 73 69 68 67 64<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 39W 43<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.68<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LK 400 .-..<br />

HFG<br />

Conversion factor F for 5LK 400 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1 : 77 N 2: 95 N3: 99 N4: 10 0 N5: 70<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT