Hexal-a trunking system for T5 fluorescent lamps<br />

7<br />

Hexagonal structured aluminium, direct distribution<br />

Specular BAP60/C<strong>at</strong>.2 louvre Hexal-a with prism<strong>at</strong>ic diffuser Hexal-a with opal diffuser Fe<strong>at</strong>ure end cap accessory<br />

Accessories<br />

Optical<br />

Code<br />

BAP60/C<strong>at</strong>.2 specular louvre<br />

f. 28W/54W, L=1197mm 5LE 982 1-1UR<br />

f. 35W/80W, L=1497mm 5LE 982 1-1RR<br />

M<strong>at</strong>t crossblade louvre<br />

f. 28W/54W, L=1197mm 5LE 980 1-1UR<br />

f. 35W/80W, L=1497mm 5LE 980 1-1RR<br />

White plain louvre<br />

f. 28W/54W, L=1197mm 5LE 981 1-1UR<br />

f. 35W/80W, L=1497mm 5LE 981 1-1RR<br />

Prism<strong>at</strong>ic diffuser<br />

f. 28W/54W, L=1197mm 5LE 981 1-1UG<br />

f. 35W/80W, L=1497mm 5LE 981 1-1RG<br />

Opal diffuser<br />

f. 28W/54W, L=1197mm 5LE 981 1-1UH<br />

f. 35W/80W, L=1497mm 5LE 981 1-1RH<br />

Housing<br />

End cap<br />

Aluminium<br />

fe<strong>at</strong>ure – silver<br />

plastic – white<br />

Jointing connector<br />

Joint covers<br />

silver<br />

white<br />

Trunking cover<br />

silver<br />

white<br />

Code<br />

5LJ 900 1-0ED<br />

5LJ 900 1-2ED<br />

5LJ 900 1-0XV<br />

5LJ 900 4-0ED<br />

5LJ 900 2-0ED<br />

5LJ 900 3-0ED1<br />

5LJ 900 3-0ED<br />

• For detailed description and<br />

dimensions – see page 7/21, optical<br />

accessories – see page 7/20<br />

• Max. distance between supports =<br />

4.0m, max. distance of support from<br />

end of row = 0.5m<br />

• System overview – see page 7/4<br />

Mounting<br />

Code<br />

Ceiling hanger 5LJ 900 3-0XC<br />

Wire hanger with 2m wire,<br />

loop ended<br />

5LJ 900 2-0XC<br />

Wire hanger with 2m wire<br />

and ceiling support<br />

Without<br />

5LJ 900 7-0XC<br />

terminal block<br />

With 5 pole<br />

5LJ 900 8-0XC<br />

terminal block<br />

End cap wire hanger, with ceiling<br />

mounting component and end cap<br />

With 2m wire<br />

5LJ 900 5-0ED<br />

Additional ceiling mounting<br />

component and<br />

5 pole terminal block 5LJ 900 9-0XC<br />

Additional wire 6m 5LK 913 0-0<br />

Wall or ceiling mounting<br />

pendant support<br />

With 0.15m tube 5LJ 900 0-0ED<br />

Hanging clip, s.s. 5LJ 900 6-0XC<br />

Chain hanger<br />

5LJ 900 1-0XC<br />

Chain, s.s. 5LY 900 2<br />

Quick-release link, s.s. 5LY 900 4<br />

Chain, galvanised 5LY 900 1<br />

Quick-release link, galv. 5LY 900 3<br />

Install<strong>at</strong>ion and refurbishment sets<br />

Hexal – DUS<br />

5LJ 900 4-0XC<br />

Hexal – DUS-classic 5LJ 900 5-0XC<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Refurbishment<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

7<br />

Luminaire : 5LJ 913 7-1U with 1 x 54W and HFG ( Lumen output : 1 x 4400 lm)<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) =85%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 0.9 1. 0 2.6 2.9 4.3 4.8 6.5 7. 2<br />

30 1. 2 1. 3 3. 6 4.0 6.0 6.6 9.0 10<br />

40 1. 5 1. 7 4.6 5.0 7. 6 8.3 11 12<br />

50 1. 8 2.0 5.5 6.0 9.2 10 14 15<br />

75 2.6 2.8 7. 9 8.4 13 14 20 21<br />

100 3. 5 3. 6 10 11 17 18 26 27<br />

200 6.5 6.8 20 20 33 34 49 51<br />

500 16 16 48 48 80 81 120 121<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 42 34 41 34 39 33 33 28<br />

0.80 53 44 51 44 48 43 42 37<br />

1.00 63 53 60 54 57 52 51 46<br />

1.25 70 59 66 60 62 57 57 52<br />

1.50 76 64 71 66 67 63 62 57<br />

2.00 84 71 78 73 73 69 68 64<br />

3.00 92 77 84 80 78 75 74 70<br />

5.00 99 83 90 87 83 81 79 76<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 2 8W 31<br />

1 x 5 4W 62<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.57<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LJ 913 .-..<br />

HFG<br />

7-1 P 1 x 28W 1. 65<br />

7-1 U 1 x 5 4W 1. 00<br />

Conversion factor F for 5LJ 913 .-..<br />

HFG<br />

7-1 P 1 x 28W 1.02<br />

7-1 U 1 x 5 4W 1.00<br />

Classific<strong>at</strong>ion<br />

DIN A 4 0<br />

CIE N1: 56 N2: 86 N3: 99 N4: 100 N 5: 85<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT