22<br />

Recessed downlights for compact fluorescent lamps Lunis®<br />

Extreme wide beam<br />

2<br />

Fe<strong>at</strong>ures<br />

High quality downlighter with a<br />

modular design for high flexibility,<br />

easy light planning and simple<br />

install<strong>at</strong>ion. Low install<strong>at</strong>ion depth<br />

for shallow ceiling void areas. Flush<br />

finish due to the wide reflector<br />

flange. Excellent value for money.<br />

Housing<br />

The luminaire has three main<br />

components; reflector, mounting<br />

ring and gearbox unit. The separ<strong>at</strong>e<br />

gearbox of the luminaire can be<br />

mounted loose or hung in the ceiling<br />

void. For ceiling thicknesses<br />

between 5 to 25mm. Installed<br />

without tools. Install<strong>at</strong>ion depth =<br />

fitting depth. Visible diameter<br />

230mm.<br />

Electrical<br />

Gearbox with low-loss (p.f. corrected),<br />

high frequency electronic control<br />

gear or 1-10V high frequency<br />

dimming gear. Connection via 3 pole<br />

terminal block max. 2,5mm 2 cable<br />

suitable for looping connections.<br />

Various electrical connections e.g.<br />

separ<strong>at</strong>e switching, plug/socket<br />

connections or emergency light if<br />

requested.<br />

Unit dimensions remain the same<br />

irrespective of lamp/gear<br />

arrangement.<br />

Lighting Technology<br />

Highly specular reflector made of<br />

pure aluminium (99,98%) (semispecular<br />

on request). Horizontal<br />

lamp orient<strong>at</strong>ion with extreme wide<br />

beam light distribution. Complies<br />

with BAP60/C<strong>at</strong>.2 with add-on kit<br />

cross baffle or turbo louvre.<br />

Recommended Applic<strong>at</strong>ions<br />

Circul<strong>at</strong>ion zones, meeting rooms,<br />

office areas (BAP60/C<strong>at</strong>.2 with addon<br />

kit raster), retail and sales zones.<br />

Code Lamps DA RD Weight<br />

[mm] [kg]<br />

Single lamp<br />

HFG<br />

5LR 114 7-1FA61 1 x TC-DEL 13W 212 115 0,8+0,4<br />

5LR 114 7-1JA61 1 x TC-TEL 13W 212 115 0,8+0,4<br />

5LR 114 7-1GA61 1 x TC-DEL 18W 212 115 0,8+0,4<br />

5LR 114 7-1KA61 1 x TC-TEL 18W 212 115 0,8+0,4<br />

5LR 114 7-1HA61 1 x TC-DEL 26W 212 115 0,8+0,4<br />

5LR 114 7-1LA61 1 x TC-TEL 26W 212 115 0,8+0,4<br />

5LR 114 7-1MA61 1 x TC-TEL 32W 212 115 0,8+0,4<br />

5LR 114 7-1NA61 1 x TC-TEL 42W 212 115 0,8+0,4<br />

HF-Dimming<br />

5LR 114 6-1FA61 1 x TC-DEL 13W 212 115 0,8+0,4<br />

5LR 114 6-1JA61 1 x TC-TEL 13W 212 115 0,8+0,4<br />

5LR 114 6-1GA61 1 x TC-DEL 18W 212 115 0,8+0,4<br />

5LR 114 6-1KA61 1 x TC-TEL 18W 212 115 0,8+0,4<br />

5LR 114 6-1HA61 1 x TC-DEL 26W 212 115 0,8+0,4<br />

5LR 114 6-1LA61 1 x TC-TEL 26W 212 115 0,8+0,4<br />

5LR 114 6-1MA61 1 x TC-TEL 32W 212 115 0,8+0,4<br />

5LR 114 6-1NA61 1 x TC-TEL 42W 212 115 0,8+0,41)<br />

Low-loss<br />

5LR 114 B-1FA61 1 x TC-D 13W 212 115 0,8+0,8<br />

5LR 114 B-1JA61 1 x TC-T 13W 212 115 0,8+0,8<br />

5LR 114 B-1GA61 1 x TC-D 18W 212 115 0,8+0,8<br />

5LR 114 B-1KA61 1 x TC-T 18W 212 115 0,8+0,8<br />

5LR 114 B-1HA61 1 x TC-D 26W 212 115 0,8+0,8<br />

5LR 114 B-1LA61 1 x TC-T 26W 212 115 0,8+0,8<br />

Code Lamps DA RD Weight<br />

[mm] [kg]<br />

Twin lamp<br />

HFG<br />

5LR 114 7-2FA61 2 x TC-DEL 13W 212 115 0,8+0,8<br />

5LR 114 7-2JA61 2 x TC-TEL 13W 212 115 0,8+0,8<br />

5LR 114 7-2GA61 2 x TC-DEL 18W 212 115 0,8+0,8<br />

5LR 114 7-2KA61 2 x TC-TEL 18W 212 115 0,8+0,8<br />

5LR 114 7-2HA61 2 x TC-DEL 26W 212 115 0,8+0,8<br />

5LR 114 7-2LA61 2 x TC-TEL 26W 212 115 0,8+0,8<br />

5LR 114 7-2MA61 2 x TC-TEL 32W 212 115 0,8+0,8<br />

5LR 114 7-2NA61 2 x TC-TEL 42W 212 115 0,8+0,8<br />

HF-Dimming<br />

5LR 114 6-2FA61 2 x TC-DEL 13W 212 115 0,8+0,8<br />

5LR 114 6-2JA61 2 x TC-TEL 13W 212 115 0,8+0,8<br />

5LR 114 6-2GA61 2 x TC-DEL 18W 212 115 0,8+0,8<br />

5LR 114 6-2KA61 2 x TC-TEL 18W 212 115 0,8+0,8<br />

5LR 114 6-2HA61 2 x TC-DEL 26W 212 115 0,8+0,8<br />

5LR 114 6-2LA61 2 x TC-TEL 26W 212 115 0,8+0,8<br />

5LR 114 6-2MA61 2 x TC-TEL 32W 212 115 0,8+0,8<br />

5LR 114 6-2NA61 2 x TC-TEL 42W 212 115 0,8+0,81)<br />

Low-loss<br />

5LR 114 B-2FA61 2 x TC-D 13W 212 115 0,8+1,2<br />

5LR 114 B-2JA61 2 x TC-T 13W 212 115 0,8+1,2<br />

5LR 114 B-2GA61 2 x TC-D 18W 212 115 0,8+1,2<br />

5LR 114 B-2KA61 2 x TC-T 18W 212 115 0,8+1,2<br />

5LR 114 B-2HA61 2 x TC-D 26W 212 115 0,8+1,2<br />

5LR 114 B-2LA61 2 x TC-T 26W 212 115 0,8+1,2<br />

• 13W downlights can also be fitted with 10W lamps.<br />

• For luminaires with TC-TEL 26W, 32W or 42W we<br />

recommend the use of OSRAM DULUX T/E IN or<br />

Philips PL-T lamps.<br />

• For dimensions see page 2/49.<br />