Hexal-a trunking system for T8 fluorescent lamps<br />

15<br />

Hexagonal structured steel, direct distribution<br />

Hexal-s with white end cap Hexal-s with trunking cover End cap accessory Supermarket, lit with Hexal-s<br />

Accessories<br />

Optical<br />

Code<br />

M<strong>at</strong>t crossblade louvre<br />

f. 36W, L=1255mm 5LE 980 1-1CR<br />

f. 58W, L=1555mm 5LE 980 1-1ER<br />

White plain louvre<br />

f. 36W, L=1255mm 5LE 981 1-1CR<br />

f. 58W, L=1555mm 5LE 981 1-1ER<br />

Prism<strong>at</strong>ic diffuser<br />

f. 36W, L=1255mm 5LE 981 1-1CG<br />

f. 58W, L=1555mm 5LE 981 1-1EG<br />

Opal diffuser<br />

f. 36W, L=1255mm 5LE 981 1-1CH<br />

f. 58W, L=1555mm 5LE 981 1-1EH<br />

Housing<br />

End cap<br />

Aluminium<br />

fe<strong>at</strong>ure – silver<br />

plastic – white<br />

Jointing connector<br />

Joint covers<br />

silver<br />

white<br />

Trunking cover<br />

silver<br />

white<br />

Code<br />

5LJ 900 1-0ED<br />

5LJ 900 1-2ED<br />

5LJ 900 1-0XV<br />

5LJ 900 4-0ED<br />

5LJ 900 2-0ED<br />

5LJ 900 3-0ED1<br />

5LJ 900 3-0ED<br />

• For detailed description and<br />

dimensions – see page 7/21, optical<br />

accessories – see page 7/20<br />

• Max. distance between supports =<br />

4,0m, max. distance of support from<br />

end of row = 0,5m<br />

• System overview – see page 7/4<br />

Mounting<br />

Code<br />

Ceiling hanger 5LJ 900 3-0XC<br />

Wire hanger with 2m wire,<br />

loop ended<br />

5LJ 900 2-0XC<br />

Wire hanger with 2m wire<br />

and ceiling support<br />

Without<br />

5LJ 900 7-0XC<br />

terminal block<br />

With 5-pole<br />

5LJ 900 8-0XC<br />

terminal block<br />

End cap wire hanger, with ceiling<br />

mounting component and end cap<br />

With 2m wire<br />

5LJ 900 5-0ED<br />

Additional ceiling mounting<br />

component and<br />

5 pole terminal block 5LJ 900 9-0XC<br />

Additional wire 6m 5LK 913 0-0<br />

Wall or ceiling mounting<br />

pendant support<br />

With 0.15m tube 5LJ 900 0-0ED<br />

Hanging clip, s.s. 5LJ 900 6-0XC<br />

Chain hanger<br />

5LJ 900 1-0XC<br />

Chain, s.s. 5LJ 900 2<br />

Quick-release link, s.s. 5LJ 900 4<br />

Chain, galvanised 5LJ 900 1<br />

Quick-release link, galv 5LJ 900 3<br />

Install<strong>at</strong>ion and refurbishment sets<br />

Hexal – DUS<br />

5LJ 900 4-0XC<br />

Hexal – DUS-classic 5LJ 900 5-0XC<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Refurbishment<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

7<br />

Luminaire : 5LJ 914 7-1 E with 1 x 58W and HFG ( Lumen output : 1 x 5000 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 77%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1. 0 1. 2 3. 1 3. 5 5.2 5.8 7. 7 8.7<br />

30 1. 4 1. 6 4.3 4.8 7. 1 8.0 11 12<br />

40 1. 8 2.0 5.4 6.0 9.0 9.9 14 15<br />

50 2.2 2.4 6.5 7. 1 11 12 16 18<br />

75 3. 0 3. 3 9.1 10 15 17 23 25<br />

100 3. 7 4.2 11 13 19 21 28 32<br />

200 6.7 7. 2 20 22 33 36 50 54<br />

500 16 16 48 48 79 80 119 120<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 36 28 35 29 33 28 28 23<br />

0.80 42 33 40 33 38 32 31 26<br />

1.00 47 37 44 37 41 36 35 29<br />

1.25 52 41 49 42 45 40 39 33<br />

1.50 57 45 53 46 49 44 43 37<br />

2.00 63 51 58 52 54 49 48 42<br />

3.00 76 63 70 65 64 61 60 55<br />

5.00 89 75 81 78 74 72 71 68<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 36W 34<br />

1 x 58W 53<br />

Light distribution to DIN 5040<br />

ϕ u 1.00<br />

ϕ su 0.53<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LJ 914 .-..<br />

HFG<br />

7-1 C 1 x 36W 1. 52<br />

7-1 E 1 x 58W 1. 00<br />

Conversion factor F for 5LJ 914 .-..<br />

HFG<br />

7-1 C 1 x 36W 1. 03<br />

7-1 E 1 x 58W 1. 00<br />

Classific<strong>at</strong>ion<br />

DIN A 4 0<br />

CIE N1: 45 N 2: 79 N3: 97 N4: 100 N 5: 77<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT