05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Surface and pendant luminaires, <strong>Siteco</strong> LP2/LP5/LP8<br />

85<br />

Accessories<br />

Through wiring kit<br />

From luminaire to luminaire<br />

For 28W or 36W<br />

3 x 1,5mm 2 5LY 911 5<br />

5 x 1,5mm 2 5LY 911 7<br />

For 35W or 58W<br />

3 x 1,5mm 2 5LY 911 6<br />

5 x 1,5mm 2 5LY 911 8<br />

• For individual luminaires please<br />

order through wiring separ<strong>at</strong>ely<br />

• For individual luminaires with 5-<br />

way through wiring an additional 2<br />

pole connection terminal (L2, L3) is<br />

required.<br />

Central jointing suspension<br />

wire hanger<br />

For secure connection of<br />

suspended continuous row<br />

luminaires.<br />

For central suspension over the<br />

luminaire joint.<br />

Code 5LP 912 0-5B<br />

• For single wire (5LP 912 ..), twin<br />

wire (5LP 913 ..) and tubular<br />

suspension (5LP 915../5LP 916..).<br />

4<br />

Additional terminal block<br />

For 5-way through wiring in<br />

individual luminaires,<br />

2 pole (L2, L3) max. 2,5mm 2<br />

cable<br />

Code<br />

5LJ 800 0-2XK<br />

• 1 piece required per luminaire.<br />

For suspended install<strong>at</strong>ion of<br />

direct distribution individual<br />

luminaires.<br />

3 pole (L1, N, E), max 2,5mm 2<br />

cable.<br />

Code<br />

5LJ 800 0-3XK<br />

• An additional through wiring is<br />

required per connection point.<br />

• With 5-way wiring an additional 2<br />

pole terminal block is required.<br />

Through wiring grommet<br />

To protect through wiring in<br />

continuously mounted<br />

individual luminaires and to<br />

align the luminaires.<br />

Code 5LY 918 3<br />

Luminaire joint bracket<br />

For secure connection of<br />

suspended continuous row<br />

luminaires.<br />

Code 5LL 920 0-2<br />

• For central joint wire suspension<br />

(5LP 912…/5LP 913..)<br />

• On suspension with complete set<br />

(5LL 911../5LL 915..) the suspension<br />

position can be either side of the<br />

joint but not on the joint line itself.<br />

• Pendant suspension (5LP 915../5LP<br />

916..) is not possible<br />

Additional support bracket<br />

For suspension of surface<br />

luminaires with wider body<br />

(Width = 325mm) on twin wire<br />

suspension (5LP 913..) or<br />

tubular pendant (5LP 915../5LP<br />

916..)<br />

Code 5LP 912 0-2B<br />

• 1 additional support bracket is<br />

required per suspension point on<br />

twin wire and tubular suspension.<br />

E14 emergency lampholder<br />

With connection terminal and<br />

fuse (G0, 4A/250V) for tubular<br />

E14 lamp, max. 40W<br />

Lamp dimensions:<br />

L ≤ 85mm, D ≤ 30mm<br />

Code 5LL 960 0-1<br />

• Retrofit is possible due to knockout<br />

in luminaire housing. One<br />

louvre side cheek has to be cut<br />

away (according to supplied<br />

install<strong>at</strong>ion instructions). Supplied<br />

with lamp on request.