05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Mounting rails<br />

37<br />

DUS trunking, galvanised steel<br />

Ceiling <strong>at</strong>tachment<br />

Galvanised steel, inc. spacer<br />

washer<br />

R<strong>at</strong>ed load: 20kg<br />

Chain suspension<br />

With height adjustment,<br />

without chain.<br />

Galvanised steel<br />

R<strong>at</strong>ed load: 20kg<br />

Wire suspension<br />

With variable height<br />

adjustment, inc. steel cable<br />

with loop end<br />

Wire: D = 1,5mm<br />

Wire: L = 1m<br />

Wire: L = 2m<br />

Chain suspension<br />

With height adjustment, lowprofile<br />

bracket, without chain,<br />

galvanised steel, partial cast<br />

aluminium.<br />

R<strong>at</strong>ed load: 20kg<br />

Chain suspension<br />

With height adjustment inc.<br />

support hook, quick-release<br />

link and ceiling mount,<br />

without chain, galvanised<br />

steel, partial aluminium<br />

casting.<br />

R<strong>at</strong>ed load: 20kg<br />

Chain, galvanised<br />

R<strong>at</strong>ed load: 90kg<br />

Link-size 8,5mm x 41mm<br />

•Per Meter<br />

The number of install<strong>at</strong>ion points is calcul<strong>at</strong>ed from the weight<br />

of the complete continuous row (rail and luminaire) and the<br />

maximum load of the suspension system. The maximum<br />

recommended distance between two install<strong>at</strong>ion points and the<br />

maximum length of the unsupported free ends should not be<br />

exceeded.<br />

Quick-release link, galvanised<br />

R<strong>at</strong>ed load: 50kg<br />

Link-size 8,0mm x 20mm<br />

9<br />

Maximum allowable distance between two install<strong>at</strong>ion points:<br />

Lmax= 3,5m<br />

Maximum allowable length of the unsupported free end Lamax=<br />

0,8m.<br />

Install<strong>at</strong>ion accessories 3<br />

For the mechanical mounting<br />

of Europlex luminaires or<br />

Comfit®/SLF on DUS trunking.<br />

• 2 pieces required per<br />

Luminaire<br />

• Wiring between<br />

luminaires<br />

on the rear with enclosed<br />

wiring (e.g. PVC).<br />

Install<strong>at</strong>ion set 4<br />

For install<strong>at</strong>ion of Comfit®/SLF<br />

Plus surface luminaires on prewired<br />

DUS trunking.<br />

Install<strong>at</strong>ion set inc. connection<br />

wiring and 3 pole plugs, with<br />

circuit selection for connection<br />

into the 5 pole sockets of the<br />

ready-wired DUS trunking.<br />

(1 set = 2 pieces)<br />

• 2 pieces required per<br />

luminaire<br />

• Pre-wired DUS trunking and<br />

accessories see page 7/28.