05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Surface and pendant luminaires, <strong>Siteco</strong> LP2/LP5<br />

67<br />

BAP60/C<strong>at</strong>.2 semi-specular louvre – direct distribution<br />

4 lamp version<br />

Continuous row luminaire<br />

without end cap<br />

Cable entry point with<br />

terminal block<br />

Louvre suspended from<br />

safety cords<br />

4<br />

Accessories<br />

Housing<br />

Code<br />

End cap set 5LP 940 1-1<br />

Variable joint connector<br />

Short arm 5LP 940 1-5<br />

Long arm 5LP 940 1-6<br />

Counter-weight<br />

For luminaires with low-loss gear<br />

1 x 18W, 2 x 18W 5LL 920 0-3<br />

1 x 36W 5LL 920 0-3<br />

1 x 58W 5LL 920 0-5<br />

For luminaires with<br />

high frequency gear<br />

1 x 28W/36W 5LL 920 0-3E<br />

1 x 35W/58W 5LL 920 0-3E<br />

2 x 28W/36W 5LL 920 0-5E<br />

2 x 35W/58W 5LL 920 0-5E<br />

Electrical<br />

Code<br />

Through wiring for 28W/36W<br />

3 x 1,5mm 2 5LY 911 5<br />

5 x 1,5mm 2 5LY 911 7<br />

Through wiring for 35W/58W<br />

3 x 1,5mm 2 5LY 911 6<br />

5 x 1,5mm 2 5LY 911 8<br />

Additional terminal<br />

block (L,N,E)<br />

5LJ 800 0-3XK<br />

Additional terminal<br />

block (L2,L3)<br />

5LJ 800 0-2XK<br />

Wiring channel 5LY 918 3<br />

E14 emergency<br />

lampholder 5LL 960 0-1<br />

Mounting<br />

Code<br />

Complete set (for ceiling mounting)<br />

single wire hanger 400mm drop<br />

Set for individual<br />

luminaire 1) 5LL 911 1-1<br />

Jointing kit 1) 5LL 911 0-1<br />

Pendant suspension 400mm drop<br />

Set for individual<br />

luminaire 1) 5LL 915 1-1<br />

Jointing kit 1) 5LL 915 0-1<br />

Single wire hanger 1)<br />

(for ceiling mounting)<br />

1000mm variable without<br />

terminal block 5LP 912 0-1X<br />

with 5 pole<br />

terminal block 5LP 912 1-1X<br />

Additional<br />

wire, 2 x 3m 5LP 912 0-3S<br />

Twin wire hanger 1)<br />

(for ceiling mounting)<br />

1000mm variable<br />

without terminal block 5LP 913 0-1X<br />

with 5 pole<br />

terminal block 5LP 913 1-1X<br />

Additional wire, 2 x 3m 5LP 913 0-3S<br />

Mounting<br />

Code<br />

Tubular pendant 1) (for ceiling<br />

mounting) 400mm drop without<br />

terminal block 5LP 915 0-1X<br />

with 5 pole terminal block,<br />

5 x 1,5mm 2 5LP 915 1-1X<br />

1000mm drop without<br />

terminal block 5LP 916 0-1X<br />

with 5 pole terminal<br />

block, 5 x 1,5mm 2 5LP 916 1-1X<br />

central suspension 5LP 912 0-5B<br />

luminaire joint bracket 1) 5LL 920 0-2<br />

Install<strong>at</strong>ion set 4: for mounting within<br />

wired DUS trunking 5LJ 909 4-0XC<br />

1) When the wider housings are to be<br />

suspended, additional mounting<br />

brackets will be necessary.<br />

• Detailed description and additional<br />

accessories see page 4/84<br />

• Suspended systems with continuous<br />

row mounting see page 4/90<br />

• Dimensions see page 4/92<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Emergency conversion<br />

components 10/22<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Luminaire : 5LP 214 7-1 E with 1 x 58W and HFG ( Lumen output : 1 x 5000 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 57%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1. 0 1. 1 3. 1 3. 4 5.2 5.7 7. 8 8.5<br />

30 1. 5 1. 6 4.4 4.8 7. 3 8.0 11 12<br />

40 1. 9 2.0 5.6 6.1 9.4 10 14 15<br />

50 2.3 2.4 6.9 7. 3 11 12 17 18<br />

75 3. 3 3. 5 9.9 10 17 17 25 26<br />

100 4.4 4.5 13 14 22 23 33 34<br />

200 8.5 8.7 25 26 42 43 63 65<br />

500 21 21 63 63 104 105 157 158<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 34 28 33 29 31 28 28 25<br />

0.80 42 36 40 36 38 35 35 32<br />

1.00 49 43 47 43 44 42 42 39<br />

1.25 53 46 50 47 48 45 45 43<br />

1.50 57 50 54 51 51 49 48 46<br />

2.00 62 54 58 55 54 53 52 50<br />

3.00 66 57 61 59 57 56 55 53<br />

5.00 70 59 63 62 58 58 57 55<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps HFG Low-loss<br />

1 x 36W 34 42<br />

1 x 58W 53 67<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.67<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LP 214 .-..<br />

HFG<br />

Low-loss<br />

7-1 C 1 x 36W 1. 47 1-1 C 1 x 36W 1. 48<br />

7-1 E 1 x 58W 1. 00 1-1 E 1 x 58W 0.98<br />

Conversion factor F for 5LP 214 .-..<br />

HFG<br />

Low-loss<br />

7-1 C 1 x 36W 1. 06 1-1 C 1 x 36W 1. 01<br />

7-1 E 1 x 58W 1. 00 1-1 E 1 x 58W 0.98<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1: 71 N 2: 99 N3: 100 N 4: 100 N 5: 57<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!