Recessed downlights for compact fluorescent lamps Lunis®<br />

25<br />

Wide beam<br />

2<br />

Gearbox can be suspended in<br />

the ceiling void<br />

Details of standard switchstart<br />

gearbox unit with lead and plug<br />

Cover-glass, fully frosted finish<br />

Accessories<br />

Optical<br />

Code<br />

Accessory suspended glass diffuser<br />

Inner frosted finish 5LR 951 6-3EJ<br />

Outer frosted finish 5LR 951 6-3EK<br />

Totally frosted finish 5LR 951 6-3EL<br />

Accessory cover glass IP44<br />

Inner frosted finish 5LR 951 6-3EB<br />

Outer frosted finish 5LR 951 6-3EF<br />

Totally frosted finish 5LR 951 6-3EE<br />

Clear<br />

5LR 951 6-3EA<br />

Accessory cover glass IP54<br />

Inner frosted finish 5LR 951 6-3ED<br />

Outer frosted finish 5LR 951 6-3EH<br />

Totally frosted finish 5LR 951 6-3EG<br />

Clear<br />

5LR 951 6-3EC<br />

Housing<br />

Code<br />

Decor<strong>at</strong>ive silicon bezel<br />

white<br />

5LR 951 6-4GP<br />

blue<br />

5LR 951 6-6GP<br />

• Notes<br />

Luminaires exceeding a w<strong>at</strong>tage<br />

totalling more than 36W should not<br />

have any cover glasses due to<br />

thermal consider<strong>at</strong>ions.<br />

Electrical<br />

Code<br />

2 pole additional 5LJ 800 0-2XK<br />

terminal block<br />

Cable<br />

5LJ 800 0-2XW<br />

strain relief<br />

3 hour emergency 5LR 112 x-xxx 61-03<br />

conversion 1)<br />

1 hour emergency 5LR 112 x-xxx 61-02<br />

conversion 1)<br />

E14 emergency 5LR 112 x-xxx 61-01<br />

lampholder 1)<br />

Mounting<br />

Code<br />

Concrete<br />

5LR 911 6-0BD<br />

casting box<br />

Panel ceiling pl<strong>at</strong>e 5LR 911 6-4BG<br />

Plastered aperture 5LR 911 6-0BC<br />

ceiling ring<br />

Cut aperture<br />

5LR 911 6-0BF<br />

ceiling ring<br />

Backing pl<strong>at</strong>e<br />

5LR 911 6-0BA<br />

1)Please note the specific<strong>at</strong>ions for the<br />

emergency unit on page 2/48.<br />

• Please specify the order number of<br />

the emergency unit with the relevant<br />

downlighter.<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Power factor correction<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

Luminaire : 5LR 112 7-2GA61 with 2 x TC-DEL 18W and HFG ( Lumen output : 2 x 1200 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 62%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 200 300 500<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1. 9 2.0 3. 7 4.1 5.6 6.1 9.3 10<br />

30 2.6 2.9 5.3 5.7 7. 9 8.6 13 14<br />

40 3. 4 3. 6 6.8 7. 3 10 11 17 18<br />

50 4.2 4.4 8.3 8.8 12 13 21 22<br />

75 6.1 6.3 12 13 18 19 30 32<br />

100 8.0 8.2 16 16 24 25 40 41<br />

200 16 16 31 32 47 48 78 80<br />

500 38 39 77 77 115 116 192 193<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 37 32 36 32 35 31 31 28<br />

0.80 46 39 44 40 42 39 39 35<br />

1.00 54 47 51 48 49 46 46 43<br />

1.25 58 50 55 52 52 50 49 46<br />

1.50 62 54 58 55 55 53 52 50<br />

2.00 67 58 62 60 58 57 56 54<br />

3.00 71 60 65 63 60 59 58 56<br />

5.00 74 63 67 66 62 61 60 58<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

2 x 1 8W 33<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.72<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LR 112 .-..<br />

HFG<br />

Conversion factor F for 5LR 112 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 6 0<br />

CIE N1: 80 N2: 100 N 3: 100 N 4: 100 N 5: 62<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT