05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

68<br />

Surface and pendant luminaires, <strong>Siteco</strong> LP2/LP5<br />

BAP60/C<strong>at</strong>.2 semi-specular louvre – direct/indirect distribution<br />

Fe<strong>at</strong>ures<br />

Single or continuous, surface or<br />

suspended low profile luminaire. A<br />

wide variety of louvre options are<br />

available including continuous louvre<br />

appearance versions. Direct or<br />

direct/indirect lighting distributions<br />

are available.<br />

4<br />

Special Fe<strong>at</strong>ures<br />

Due to the constant luminaire crosssection,<br />

various combin<strong>at</strong>ions of single<br />

and twin lamp luminaires with T5 and<br />

T8 lamps are possible. Due to the<br />

consistent housing dimensions the<br />

louvres are exchangeable even when<br />

with different lamps are used (e.g. T5,<br />

T8). The variable angle jointing<br />

connector allows highly flexible two<br />

dimensional lighting configur<strong>at</strong>ions.<br />

Housing<br />

Housing made from white finished<br />

sheet steel (similar to RAL 9010).<br />

Housings for continuous row<br />

mounting are without end pl<strong>at</strong>es to<br />

enable a continual louvre appearance.<br />

The louvres are secured in the frame by<br />

spring c<strong>at</strong>ches. When being<br />

maintained the louvres hang on<br />

earthing safety retaining cords and are<br />

therefore still integr<strong>at</strong>ed into the<br />

earthing safety system.<br />

Electrical<br />

Luminaires wired with 5 pole<br />

(individual luminaires with 3 pole)<br />

terminal block, max. 2,5mm 2 cable.<br />

Standard version supplied with<br />

switchstart or high frequency<br />

electronic gear. The individual<br />

luminaire body end caps are fitted<br />

with knock-outs for wiring entry and<br />

the continuous luminaires can be used<br />

for through wiring. Instabus EIB and<br />

high frequency dimming on request.<br />

Lighting Technology<br />

BAP60/C<strong>at</strong>.2 semi-specular anodised<br />

aluminium louvres. L ≤ 1000cd/m 2 for<br />

axial/transverse angles ≥ 60° (65° all<br />

round). Direct/indirect distribution -<br />

approxim<strong>at</strong>ely 30% indirect.<br />

Continuous luminaire<br />

Code Lamps L1 W H Wt.<br />

[mm]<br />

[kg]<br />

Direct/indirect distribution<br />

HFG, T5<br />

5LP 534 7-1P 1 x 28W 1224 210 80+7 3,8<br />

5LP 534 7-1R 1 x 35W 1524 210 80+7 4,7<br />

5LP 534 7-5P 2 x 28W 1224 210 80+7 3,9<br />

5LP 534 7-5R 2 x 35W 1524 210 80+7 4,9<br />

HFG, T8<br />

5LP 534 7-1C 1 x 36W 1224 210 80+7 3,8<br />

5LP 534 7-1E 1 x 58W 1524 210 80+7 4,7<br />

5LP 534 7-5C 2 x 36W 1224 210 80+7 3,9<br />

5LP 534 7-5E 2 x 58W 1524 210 80+7 4,9<br />

Switchstart, T8<br />

5LP 534 2-1C 1 x 36W 1224 210 80+7 4,3<br />

5LP 534 2-1E 1 x 58W 1524 210 80+7 5,4<br />

5LP 534 2-5C 2 x 36W 1224 210 80+7 5,1<br />

5LP 534 2-5E 2 x 58W 1524 210 80+7 6,6<br />

1) Luminaires supplied without endcaps,<br />

please order separ<strong>at</strong>ely<br />

Individual luminaire<br />

Code Lamps L1 W H Wt.<br />

[mm]<br />

[kg]<br />

Direct/indirect distribution<br />

HFG, T5<br />

5LP 234 7-1M 1 x 14W 623 210 80+7 2,1<br />

5LP 234 7-1P 1 x 28W 1248 210 80+7 3,8<br />

5LP 234 7-1R 1 x 35W 1548 210 80+7 4,7<br />

5LP 234 7-5M 2 x 14W 623 210 80+7 2,2<br />

5LP 234 7-5P 2 x 28W 1248 210 80+7 3,9<br />

5LP 234 7-5R 2 x 35W 1548 210 80+7 4,9<br />

HFG, T8<br />

5LP 234 7-1A 1 x 18W 623 210 80+7 2,1<br />

5LP 234 7-1C 1 x 36W 1248 210 80+7 3,8<br />

5LP 234 7-1E 1 x 58W 1548 210 80+7 4,7<br />

5LP 234 7-5A 2 x 18W 623 210 80+7 2,2<br />

5LP 234 7-5C 2 x 36W 1248 210 80+7 3,9<br />

5LP 234 7-5E 2 x 58W 1548 210 80+7 4,9<br />

Switchstart, T8<br />

5LP 234 2-1A 1 x 18W 623 210 80+7 2,6<br />

5LP 234 2-1C 1 x 36W 1248 210 80+7 4,3<br />

5LP 234 2-1E 1 x 58W 1548 210 80+7 5,4<br />

5LP 234 2-5A 2 x 18W 623 210 80+7 3,2<br />

5LP 234 2-5C 2 x 36W 1248 210 80+7 5,1<br />

5LP 234 2-5E 2 x 58W 1548 210 80+7 6,6<br />

Recommended Applic<strong>at</strong>ions<br />

Office or similar environments mainly<br />

used with VDU equipment.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!