Uplights and wall luminaires, Wave<br />

5<br />

with ELDACON® light technology<br />

1<br />

Wall luminaire<br />

Asymmetric uplighter<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Photometric d<strong>at</strong>a<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion<br />

Lighting electronics<br />

Instabus EIB - principles<br />

Instabus EIB - components<br />

Dimming control<br />

Control gear<br />

Power factor correction<br />

Refurbishment<br />

Approvals<br />

Safety markings<br />

Symbols<br />

Lamp d<strong>at</strong>a<br />

Product Index<br />

C<strong>at</strong>alogue number index<br />

Chapter<br />

appendix<br />

appendix<br />

appendix<br />

on request<br />

on request<br />

on request<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

appendix<br />

Symmetrical uplighter; Design: Michael Englisch<br />

Luminaire: 5LM 478 7-4UL1 with 4 x TC-L 55W and HFG (Lumen output: 4 x 4800 lm)<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 70%<br />

Light distribution to DIN 5040<br />

ϕ u 0.07<br />

ϕ su 0.67<br />

ϕ so 0.76<br />

Isolux curves<br />

Room dimensions<br />

Length 4.80m<br />

Width 4.50m<br />

Height 3.00m<br />

Reflection factors<br />

Ceiling 80%<br />

Walls 80%<br />

Curtains 65%<br />

Floor 20%<br />

Maint. Factor 0.8<br />

Results<br />

Em (Room) 390 lx<br />

Em (Table) 510 lx<br />

Legend<br />

600 lx<br />

500 lx<br />

400 lx<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

4 x 55W 245<br />

Classific<strong>at</strong>ion<br />

DIN E 5 3<br />

CIE N1: 69 N2: 93 N3: 98 N4: 7 N5: 70<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT