34 Compact reflector luminaires, ball proof<br />

with aluminium crossblade louvre<br />

Fe<strong>at</strong>ures<br />

The compact reflector luminaire is<br />

characterised by the simple<br />

rectangular housing with its direct<br />

symmetrical beam light distribution.<br />

Special Fe<strong>at</strong>ures<br />

Ingress protection r<strong>at</strong>ing IP 65,<br />

borosilic<strong>at</strong>e glass lamp and control<br />

gear compartment cover, with<br />

damage and dust protected<br />

integr<strong>at</strong>ed aluminium crossblade<br />

louvre. The luminaire has been<br />

tested in accordance with DIN VDE<br />

0710 Part 13 for direct ceiling<br />

mounting for use in environments<br />

where ball impact resistance is<br />

required.<br />

10<br />

Housing<br />

Sealed rectangular white finished<br />

(RAL9010) sheet steel housing.<br />

Temper<strong>at</strong>ure change resistant<br />

security glass lamp and control gear<br />

cover, having s<strong>at</strong>in finish in the area<br />

of the control, secured on to hinges<br />

to fold down for maintenance and<br />

re-lamping purposes.<br />

Electrical<br />

The luminaire is wired with<br />

integr<strong>at</strong>ed 3 pole terminal block,<br />

max 2,5mm 2 cable, integr<strong>at</strong>ed fuse,<br />

(T6, 3A/250V). 2 cable entry points<br />

with gland connections PG 13,5mm<br />

(Wiring diameter 6,5 - 13mm),<br />

suitable for through wiring. The<br />

control gear compartment is<br />

separ<strong>at</strong>e from the lamp<br />

compartment. The luminaire is<br />

power factor corrected.<br />

Code Lamps L W H Wt.<br />

[mm]<br />

[kg]<br />

IP65<br />

5NX 766 2-0N HIT/HST 250W 616 300 154 11,5<br />

5NX 766 2-1E HIT/HST 250W 616 300 154 11,3<br />

Lighting Technology<br />

Anodised aluminium reflector with<br />

integr<strong>at</strong>ed s<strong>at</strong>in ribbed crossblades<br />

for low glare.<br />

Recommended Applic<strong>at</strong>ions<br />

Covered areas outdoors, areas with<br />

CCTV surveillance:<br />

-Petrol st<strong>at</strong>ions,<br />

-Storage areas,<br />

-Loading bays,<br />

-Sport stadiums.