05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Surface and pendant luminaires, <strong>Siteco</strong> LP2/LP5<br />

73<br />

Parabolic specular louvre – direct/indirect distribution<br />

Continuous row luminaire<br />

without end cap<br />

Twin wire suspension<br />

Continuous row with twin wire<br />

central hanger<br />

Detail<br />

4<br />

Accessories<br />

Optical<br />

Code<br />

Asymmetric reflector component,<br />

specular<br />

For 1 x 14W/18W 5LP 972 0-1A<br />

For 1 x 28W/36W 5LP 972 0-1C<br />

For 1 x 35W/58W 5LP 972 0-1E<br />

Housing<br />

Code<br />

End cap set 5LP 940 1-1<br />

Variable joint connector<br />

Short arm 5LP 940 1-5<br />

Long arm 5LP 940 1-6<br />

Counter-weight<br />

Low-loss: 1 x 18W/36W,<br />

2 x 18W 5LL 920 0-3<br />

Low-loss :1 x 58W 5LL 920 0-5<br />

HFG: single lamp 5LL 920 0-3E<br />

HFG: twin lamp 5LL 920 0-5E<br />

Electrical<br />

Code<br />

Through wiring for 28W/36W<br />

3 x 1,5mm 2 5LY 911 5<br />

5 x 1,5mm 2 5LY 911 7<br />

Through wiring for 35W/58W<br />

3 x 1,5mm 2 5LY 911 6<br />

5 x 1,5mm 2 5LY 911 8<br />

Additional<br />

terminal block (L,N,E) 5LJ 800 0-3XK<br />

Additional<br />

terminal block (L2,L3) 5LJ 800 0-2XK<br />

Wiring channel 5LY 918 3<br />

E14 emergency lamp. 5LL 960 0-1<br />

Mounting<br />

Code<br />

Complete set<br />

(for ceiling mounting) single wire<br />

hanger 400mm drop<br />

Set for ind. luminaire 5LL 911 1-1<br />

Jointing kit 5LL 911 0-1<br />

Pendant suspension 400mm drop<br />

Set for individual<br />

luminaire 5LL 915 1-1<br />

Jointing kit 5LL 915 0-1<br />

Single wire hanger<br />

(for ceiling mounting)<br />

1000mm variable without<br />

terminal block 5LP 912 0-1X<br />

with 5 pole<br />

terminal block 5LP 912 1-1X<br />

Additional<br />

wire, 2 x 3m 5LP 912 0-3S<br />

Twin wire hanger<br />

(for ceiling mounting)<br />

1000mm variable<br />

without terminal block 5LP 913 0-1X<br />

with 5 pole<br />

terminal block 5LP 913 1-1X<br />

Additional<br />

wire, 2 x 3m 5LP 913 0-3S<br />

Mounting<br />

Code<br />

Tubular pendant<br />

(for ceiling mounting)<br />

400mm drop<br />

without terminal block 5LP 915 0-1X<br />

with 5 pole terminal block,<br />

5 x 1,5mm 2 5LP 915 1-1X<br />

1000mm drop<br />

without terminal block 5LP 916 0-1X<br />

with 5 pole<br />

terminal block,<br />

5 x 1,5mm 2 5LP 916 1-1X<br />

central suspension 5LP 912 0-5B<br />

luminaire<br />

joint bracket 5LL 920 0-2<br />

Install<strong>at</strong>ion set 4: for mounting within<br />

wired DUS trunking 5LJ 909 4-0XC<br />

• Detailed description and additional<br />

accessories see page 4/84<br />

• Suspended systems with continuous<br />

row mounting see page 4/90<br />

• Dimensions see page 4/92<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Emergency conversion<br />

components 10/22<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Luminaire : 5LP 233 7-1 E with 1 x 58W and HFG ( Lumen output : 1 x 5000 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 76%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 0.8 0.9 2.4 2.7 4.0 4.5 6.0 6.8<br />

30 1. 1 1. 3 3. 4 3. 8 5.7 6.3 8.6 9.5<br />

40 1. 5 1. 6 4.5 4.8 7. 5 8.0 11 12<br />

50 1. 8 2.0 5.5 5.9 9.2 9.8 14 15<br />

75 2.7 2.8 8.0 8.4 13 14 20 21<br />

100 3. 5 3. 7 10 11 17 19 26 28<br />

200 6.9 7. 0 21 21 34 35 51 52<br />

500 17 17 51 51 84 85 127 128<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 35 28 34 28 31 26 26 20<br />

0.80 45 36 42 36 39 34 33 27<br />

1.00 53 44 50 44 46 42 40 34<br />

1.25 59 49 54 49 49 45 43 37<br />

1.50 63 53 58 53 52 49 46 40<br />

2.00 70 59 64 59 57 54 51 44<br />

3.00 76 63 68 64 59 57 53 46<br />

5.00 82 68 72 70 63 61 57 49<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps HFG Low-loss<br />

1 x 36W 34 42<br />

1 x 58W 53 67<br />

Light distribution to DIN 5040<br />

ϕ u 0.72<br />

ϕ su 0.65<br />

ϕ so 0.72<br />

Conversion factor F1 for 5LP 233 .-..<br />

HFG<br />

Low-loss<br />

7-1 C 1 x 36W 1. 56 1-1 C 1 x 36W 1. 49<br />

7-1 E 1 x 58W 1. 00 1-1 E 1 x 58W 0.96<br />

Conversion factor F for 5LP 233 .-..<br />

HFG<br />

Low-loss<br />

7-1 C 1 x 36W 1. 00 1-1 C 1 x 36W 1. 00<br />

7-1 E 1 x 58W 1. 00 1-1 E 1 x 58W 1. 00<br />

Classific<strong>at</strong>ion<br />

DIN B 5 3<br />

CIE N1: 70 N2: 98 N3: 100 N 4: 72 N 5: 76<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!