Recessed luminaires, <strong>Siteco</strong> LP1<br />

47<br />

BAP60/C<strong>at</strong>.2 semi-specular louvre<br />

Louvre suspended from<br />

safety cords<br />

<strong>Siteco</strong> LP1 three lamp luminaire<br />

Push out for E14 emergency<br />

lampholder<br />

E14 emergency lampholder<br />

Accessories<br />

Electrical<br />

Code<br />

2 pole (L2,L3)<br />

terminal block 5LJ 800 0-2XK<br />

E14 emergency<br />

lampholder 5LL 960 0-1<br />

Mounting<br />

Code<br />

Quick mounting brackets<br />

18-33mm<br />

5LP 900 0-0XC<br />

31-50mm<br />

5LP 900 1-0XC<br />

Support bracket – single lamp<br />

(1 set = 4 pieces) 5LP 950 1-1<br />

(1 set = 16 pieces) 5LP 950 1-4<br />

Support bracket – twin lamp<br />

(1 set = 4 pieces) 5LP 950 2-1<br />

(1 set = 16 pieces) 5LP 950 2-4<br />

• For detailed description see page 5/58<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Emergency conversion<br />

components 10/22<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

5<br />

Luminaire : 5LP 124 7-4 A with 4 x 18W and HFG ( Lumen output : 4 x 1300 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 53%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1. 0 1. 1 3. 1 3. 4 5.2 5.7 7. 8 8.5<br />

30 1. 5 1. 6 4.4 4.8 7. 3 7. 9 11 12<br />

40 1. 9 2.0 5.6 6.1 9.4 10 14 15<br />

50 2.3 2.4 6.8 7. 3 11 12 17 18<br />

75 3. 3 3. 5 9.9 10 17 17 25 26<br />

100 4.4 4.5 13 14 22 23 33 34<br />

200 8.5 8.7 25 26 42 44 63 65<br />

500 21 21 63 63 104 105 157 158<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 31 26 30 27 29 26 26 23<br />

0.80 38 33 37 33 35 32 32 29<br />

1.00 44 38 42 39 40 38 38 35<br />

1.25 48 42 45 43 43 41 40 38<br />

1.50 52 45 48 46 46 44 43 41<br />

2.00 56 49 52 50 49 48 47 45<br />

3.00 60 51 55 53 51 50 49 47<br />

5.00 63 53 57 56 53 52 51 49<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps HFG Low-loss<br />

4 x 18W 69 89<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.71<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LP 124 .-..<br />

Conversion factor F for 5LP 124 .-..<br />

HFG<br />

Low-loss<br />

HFG<br />

Low-loss<br />

7-4 A 4 x 1 8W 1. 00 1-4 A 4 x 1 8W 0.97 7-4 A 4 x 1 8W 1. 00 1-4 A 4 x 1 8W 0.99<br />

Classific<strong>at</strong>ion<br />

DIN A 6 0<br />

CIE N1: 74 N 2: 99 N3: 100 N 4: 100 N 5: 53<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT