Wing luminaire – soft light with air supply and extract<br />

9<br />

The design brief<br />

Room lighting, air supply and<br />

air extract as well as additional<br />

technical elements would have<br />

to be integr<strong>at</strong>ed within a low<br />

install<strong>at</strong>ion depth<br />

• These are custom made<br />

products with prices and<br />

availability confirmed upon<br />

request.<br />

The solution concept<br />

Extremely shallow, semirecessed<br />

housings with two<br />

perfor<strong>at</strong>ed wing sections, which<br />

give a soft curved effect within<br />

the ceiling. Along the edges are<br />

the air supply rails. The extract<br />

air passes through the louvre<br />

and the canopy.<br />

Architect<br />

Sir Norman Foster and Partners<br />

Light planner<br />

Schad + Hoelzel Engineering<br />

Company Ltd.<br />

H<br />

90<br />

L<br />

100<br />

w<br />

11<br />

Luminaire : 5LD 570 71 KU43 with 1 x 36W and HFG ( Lumen output : 1 x 3200 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 27 0<br />

Total light output r<strong>at</strong>io (LOR) = 62%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 1. 5 1. 7 4.5 5.0 7. 5 8.3 11 12<br />

30 2.1 2.3 6.3 6.9 11 12 16 17<br />

40 2.7 2.9 8.1 8.8 13 15 20 22<br />

50 3. 3 3. 5 9.8 11 16 18 25 26<br />

75 4.7 5.0 14 15 24 25 35 37<br />

100 6.2 6.4 19 19 31 32 47 48<br />

200 12 12 36 37 60 62 89 92<br />

500 29 30 88 89 14 7 14 8 22 1 22 2<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 34 28 33 28 31 27 27 24<br />

0.80 42 35 40 36 38 35 34 31<br />

1.00 50 42 47 43 45 42 41 38<br />

1.25 54 46 51 47 48 45 45 42<br />

1.50 58 50 54 51 51 49 48 45<br />

2.00 64 55 59 56 55 53 53 50<br />

3.00 68 58 63 60 58 56 56 53<br />

5.00 73 61 66 64 61 59 58 56<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 36W 34<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.65<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LD 570 .-..<br />

HFG<br />

Conversion factor F for 5LD 570 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1 : 71 N 2: 98 N3: 10 0 N4: 10 0 N5: 62<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT