Recessed luminaires, <strong>Siteco</strong> LF1<br />

31<br />

White louvre<br />

Twin lamp <strong>Siteco</strong> LF1 Luminaire housing detail White louvre Luminaire housing with T5 lamp<br />

Accessories<br />

Mounting<br />

Code<br />

Quick mounting brackets<br />

Clamping range 1-10mm<br />

1 lamp 5LF 900 0-4XC<br />

2 lamp 5LF 902 0-2XC<br />

3 lamp 5LF 902 0-3XC<br />

2 lamp<br />

600 wide version 5LF 902 1-0XC<br />

Clamping range 21-33mm<br />

1 lamp 5LF 900 1-4XC<br />

2 lamp 5LF 902 1-4XC<br />

3 lamp 5LF 902 1-4XC<br />

2 lamp<br />

600 wide version 5LF 902 1-0XC<br />

• Detailed description see page 5/32<br />

• Dimensions see page 5/33<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

5<br />

Luminaire : 5LF 127 7-3 M with 3 x 14W and HFG ( Lumen output : 3 x 1220 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 68%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

20 1. 3 1. 4 3. 9 4.3 6.4 7. 2 9.6 11<br />

30 1. 8 2.0 5.3 5.9 8.9 9.9 13 15<br />

40 2.3 2.5 6.8 7. 4 11 12 17 19<br />

50 2.7 3. 0 8.2 8.9 14 15 20 22<br />

75 3. 9 4.2 12 12 20 21 29 31<br />

100 5.2 5.4 15 16 26 27 39 40<br />

200 9.7 10 29 30 48 51 73 76<br />

500 24 24 71 72 119 120 178 180<br />

Lh = Luminaire mounting height<br />

Floor area A [m 2 ]<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 33 27 32 27 31 26 26 22<br />

0.80 42 34 40 35 38 34 33 29<br />

1.00 50 41 47 42 45 41 40 36<br />

1.25 55 46 52 47 49 45 45 41<br />

1.50 60 51 56 52 53 50 49 45<br />

2.00 67 57 62 58 58 55 54 51<br />

3.00 73 61 66 63 61 59 58 55<br />

5.00 79 66 71 69 65 64 63 60<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

3 x 14W 45<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.58<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LF 127 .-..<br />

HFG<br />

Conversion factor F for 5LF 127 .-..<br />

HFG<br />

Classific<strong>at</strong>ion<br />

DIN A 4 0<br />

CIE N1: 56 N2: 86 N3: 97 N4: 100 N 5: 68<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT