05.03.2015 Views

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

Your contact at Siteco: Name : Department ... - POWERLAB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Pendant luminaires, SiFORM for individual and continuous mounting<br />

25<br />

SECONDARY-Modul I<br />

Luminaire module for<br />

continuous mounting.<br />

Gear tray and cover detail.<br />

MUF detail showing<br />

droprod fixings<br />

4<br />

Accessories<br />

Mounting<br />

Code<br />

Multifunction rail 5LM 100 0-1<br />

Cover for MUF<br />

1,19m 5LM 100 0-4<br />

3,00m 5LM 100 0-2<br />

End caps for MUF 5LM 100 0-3<br />

• System overview see page 4/12.<br />

• Detailed description see page 4/13.<br />

• Dimensions see page 4/32.<br />

General inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Refurbishment<br />

appendix<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

Individual SECONDARY - Module I luminaire<br />

Luminaire : 5LM 17 7 7-1 RS3 with 1 x 35W and HFG ( Lumen output : 1 x 3290 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 65%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 1. 5 1. 7 4.6 5.2 7. 7 8.6 12 13<br />

30 2.2 2.4 6.5 7. 1 11 12 16 18<br />

40 2.8 3. 0 8.3 9.0 14 15 21 22<br />

50 3. 4 3. 6 10 11 17 18 25 27<br />

75 4.8 5.1 14 15 24 26 36 38<br />

100 6.1 6.6 18 20 31 33 46 49<br />

200 12 12 35 36 58 60 87 90<br />

500 28 28 84 85 141 141 211 212<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 39 33 37 33 36 32 32 28<br />

0.80 43 36 41 36 39 35 35 31<br />

1.00 47 39 45 40 42 38 38 34<br />

1.25 52 43 49 44 46 43 42 38<br />

1.50 57 47 53 49 50 46 46 42<br />

2.00 62 52 57 53 53 50 50 46<br />

3.00 70 58 64 61 59 57 56 53<br />

5.00 76 63 68 67 63 62 61 58<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps<br />

HFG<br />

1 x 28W 31<br />

1 x 35W 38<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.68<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LM 17 7 .-..<br />

HFG<br />

7-1 PS3 1 x 28W 1. 24<br />

7-1 RS3 1 x 35W 1. 00<br />

Conversion factor F for 5LM 17 7 .-..<br />

HFG<br />

7-1 PS3 1 x 28W 1. 02<br />

7-1 RS3 1 x 35W 1. 00<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1: 71 N 2: 96 N3: 100 N 4: 100 N 5: 65<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!