100<br />

Surface luminaire, Ceilingwasher<br />

Accessories<br />

Through wiring<br />

For Ceilingwasher luminaires<br />

For 36W<br />

3 x 1,5mm 2 5LY 911 5<br />

5 X 1,5mm 2 5LY 911 7<br />

For 58W<br />

3 x 1,5mm 2 5LY 911 6<br />

5 X 1,5mm 2 5LY 911 8<br />

4<br />

• In SiLING luminaires, through wiring in<br />

additional insul<strong>at</strong>ion is possible.<br />

• For 5-way through wiring, an additional 2<br />

pole terminal block (L2,L3) is required per<br />

luminaire.<br />

Additional terminal block<br />

For 5-way through wiring<br />

2 pole (L2,L3), max. 2,5mm 2 cable.<br />

Code 5LY 918 0<br />

Suspension kit<br />

For SiLING luminaires.<br />

With variable suspension drop<br />

up to 1500mm<br />

Steel wire : D=1,2mm<br />

Incl. ceiling mounting pl<strong>at</strong>e and<br />

white ceiling cover.<br />

Without terminal block<br />

Code 5LM 820 0-1<br />

With 5 pole terminal block, max.<br />

2,5mm 2 cable.<br />

Code 5LM 820 1-1<br />

Einzel -<br />

Anordnung<br />

Zwillings -<br />

Anordnung<br />

Wandfluter<br />

A<br />

C<br />

Deckenfluter<br />

B<br />

D<br />

• To mount as diagram `A` two additional<br />

connection hangers are required per<br />

single lamp luminaire.<br />

• To mount as diagram B` no additional<br />

accessories are required.<br />

• To mount as diagram `C` or `D`, two<br />

additional connection hangers are<br />

required per single lamp luminaire and<br />

four hangers per twin lamp luminaire.<br />

Connection hanger<br />

For mounting SiLING luminaires<br />

as diagram `A`<br />

(1 set = 2 pieces)<br />

Code 5LM 701 0-0<br />

• 2 pieces required per luminaire (single or<br />

twin lamp)<br />

Connection hanger<br />

For mounting SiLING luminaires<br />

as diagram `C` or diagram `D`<br />

(1 set = 2 pieces)<br />

Code 5LM 701 0-0<br />

• 2 pieces required per single lamp<br />

luminaire<br />

• 4 pieces required per twin lamp luminaire<br />

install<strong>at</strong>ion diagrams: SiLING