Recessed luminaires, <strong>Siteco</strong> LP1/LP7<br />

49<br />

Crossblade louvre<br />

Inside view of gear pod<br />

External view of gear pod<br />

Mounting accessory detail<br />

Accessories<br />

Electrical<br />

Code<br />

2 pole (L2,L3)<br />

terminal block 5LJ 800 0-2XK<br />

E14 emergency<br />

lampholder 5LL 960 0-1<br />

Mounting<br />

Code<br />

Quick mounting brackets<br />

18-33mm<br />

5LP 900 0-0XC<br />

31-50mm<br />

5LP 900 1-0XC<br />

Support bracket – single lamp<br />

(1 set = 4 pieces) 5LP 950 1-1<br />

(1 set = 16 pieces) 5LP 950 1-4<br />

Support bracket – twin lamp<br />

(1 set = 4 pieces) 5LP 950 2-1<br />

(1 set = 16 pieces) 5LP 950 2-4<br />

• For detailed description see page 5/58<br />

General Inform<strong>at</strong>ion<br />

Subject<br />

Chapter<br />

Photometric d<strong>at</strong>a<br />

appendix<br />

Applic<strong>at</strong>ion inform<strong>at</strong>ion appendix<br />

Lighting electronics appendix<br />

Instabus EIB - principles on request<br />

Instabus EIB - components on request<br />

Dimming control<br />

on request<br />

Control gear<br />

appendix<br />

Power factor correction appendix<br />

Emergency conversion<br />

components 10/22<br />

Approvals<br />

appendix<br />

Safety markings<br />

appendix<br />

Symbols<br />

appendix<br />

Lamp d<strong>at</strong>a<br />

appendix<br />

Product Index<br />

appendix<br />

C<strong>at</strong>alogue number index appendix<br />

5<br />

Luminaire : 5LP 126 7-4 A with 4 x18W and HFG ( Lumen output : 4 x 1300 lm )<br />

Light output in cd / klm<br />

Tested to DIN 5032<br />

C0 - 1 80 C90 - 270<br />

Total light output r<strong>at</strong>io (LOR) = 63%<br />

Number of luminaires in room<br />

Reflection factors :70/50/20 MF = 0.8<br />

HFG<br />

En [lx] 100 300 500 750<br />

Lh [m] 2.5 3.0 2.5 3.0 2.5 3.0 2.5 3.0<br />

Floor area A [m 2 ]<br />

20 0.9 1. 0 2.7 3. 0 4.5 5.0 6.8 7. 5<br />

30 1. 3 1. 4 3. 8 4.2 6.4 7. 0 9.5 10<br />

40 1. 6 1. 8 4.9 5.3 8.1 8.8 12 13<br />

50 2.0 2.1 5.9 6.4 9.9 11 15 16<br />

75 2.8 3. 0 8.5 9.0 14 15 21 23<br />

100 3. 8 3. 9 11 12 19 19 28 29<br />

200 7. 2 7. 5 22 22 36 37 54 56<br />

500 18 18 53 54 89 90 134 134<br />

Lh = Luminaire mounting height<br />

Utilis<strong>at</strong>ion<br />

Luminaire utilis<strong>at</strong>ion factors<br />

ρCeiling<br />

80 80 70 70 50 50 30 0<br />

ρWall<br />

50 30 50 30 50 30 30 0<br />

ρFloor<br />

30 10 20 20 10 10 10 0<br />

Room Index k<br />

0.60 35 29 34 29 32 29 28 25<br />

0.80 43 36 41 37 39 36 35 32<br />

1.00 51 43 48 44 46 43 42 39<br />

1.25 55 47 52 48 49 46 46 43<br />

1.50 59 51 55 52 52 50 49 46<br />

2.00 65 56 60 57 56 54 54 51<br />

3.00 70 59 64 61 59 58 57 54<br />

5.00 74 62 67 65 62 61 59 57<br />

Power consumption<br />

Values in W<strong>at</strong>ts<br />

Lamps HFG Low-loss<br />

4 x 18W 69 89<br />

Light distribution to DIN 5040<br />

ϕ u 1. 00<br />

ϕ su 0.66<br />

ϕ so 0.00<br />

Conversion factor F1 for 5LP 126 .-..<br />

Conversion factor F for 5LP 126 .-..<br />

HFG<br />

Low-loss<br />

HFG<br />

Low-loss<br />

7-4 A 4 x 18W 1. 00 1-4 A 4 x 18W 0.97 7-4 A 4 x 18W 1. 00 1-4 A 4 x 18W 0.99<br />

Classific<strong>at</strong>ion<br />

DIN A 5 0<br />

CIE N1: 67 N2: 94 N3: 99 N4: 100 N 5: 63<br />

Further photometric d<strong>at</strong>a can be found in our lighting design program SiLICHT