12.07.2015 Views

C•CURE 800/8000 Software Configuration Guide - Tyco Security ...

C•CURE 800/8000 Software Configuration Guide - Tyco Security ...

C•CURE 800/8000 Software Configuration Guide - Tyco Security ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Door DefinitionsTable 5-7: Configure Advanced Door Monitoring Dialog Box Definitions, continuedField/ButtonDescriptionButtonsAddRemoveRemove AllEdit InputsClick Add to move the selected input to the Selected Inputs box.Click Remove to move the selected input from the Selected Inputs boxto the Available Inputs box.Click Remove All to move all inputs from the Selected Inputs box to theAvailable Inputs box.To edit your selections, click Edit Inputs to open the Inputs Selectionbrowser, then select an Input and click Edit.TimersUnlock grace timeDoor open gracetimeDoor closedebounce timeCrash bar changetimeBond sensorchange timeLatch bolt changetimeSpecifies the time (in 1/10th of a second intervals) that the C•CURE<strong>800</strong>/<strong>800</strong>0 waits for a door open signal after the door unlock time hasexpired. Prevents a false "door forced" message in situations wheresignals are nearly simultaneous.Specifies the time (in 1/10th of a second intervals) that the C•CURE<strong>800</strong>/<strong>800</strong>0 waits for an RTE, card admit, or momentary unlock signalafter receiving the signal from the DSM. Prevents a false "door forcedopen" message in situations where signals are nearly simultaneous.Specifies the time (in 1/10th of a second intervals) that the C•CURE<strong>800</strong>/<strong>800</strong>0 ignores DSM inputs, to allow for bouncing doors.Specifies the time (in 1/10th of a second intervals) that the C•CURE<strong>800</strong>/<strong>800</strong>0 allows, after a crash bar state change, for a lock sensorchange.Specifies the time (in 1/10th of a second intervals) that the C•CURE<strong>800</strong>/<strong>800</strong>0 allows for a bond sensor state change. The C•CURE <strong>800</strong>/<strong>800</strong>0 uses this time, and the time of the other inputs configured for thedoor, to determine the wait before issuing a "lock tamper" or "lockunsecured" alarm.Specifies the time (in 1/10th of a second intervals) that the C•CURE<strong>800</strong>/<strong>800</strong>0 allows for a latch bolt state change. The C•CURE <strong>800</strong>/<strong>800</strong>0uses this time, and the time of the other inputs configured for the door,to determine the wait before issuing a "lock tamper" or "lock unsecured"alarm.C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Software</strong> <strong>Configuration</strong> <strong>Guide</strong> 5–31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!