Straight Forward EventsDoor state changes, manual action messages, and Double Swipe activitydisplay at the Monitoring Station and are entered into the journal.Sample Door Forced EventThe event in this example activates the output to a siren, sends a message, andactivates a sound at the Monitoring Station if the lobby door is forced afternormal business hours. If an officer fails to acknowledge the event, a secondevent activates. The second event sends a page to the security supervisor.To Configure a Sample Forced Door Event1. Create an event that activates the output to the siren, and specify a doorforced event on the lobby door.2. Specify officer acknowledgements, Monitoring Station sounds, andsubsequent events:a. Annunciate the event.b. Specify the sound that plays at the Monitoring Stationc. Require acknowledgement.d. If event is unacknowledged within a specific time, activate asubsequent event (the event in this example sends a page).3. Link the event with a time specification. This specifies the time that theevent is active (in this case, after business hours).7–8 C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Software</strong> <strong>Configuration</strong> <strong>Guide</strong>