12.07.2015 Views

C•CURE 800/8000 Software Configuration Guide - Tyco Security ...

C•CURE 800/8000 Software Configuration Guide - Tyco Security ...

C•CURE 800/8000 Software Configuration Guide - Tyco Security ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Intrusion Zone ModesWhen you disarm an intrusion zone, the apC or iSTAR reports the disarmedstatus to C•CURE server. If the disarm method included presenting a card,the panel reports the personnel access. For five seconds after an intrusionzone is disarmed, the system displays disarm status messages on all readerswithin the zones.The apC or iSTAR processes access requests at the intrusion zone doorsduring the disarmed state. You can gain access at the locked doors throughthe usual means: valid card, valid card and pin, or RTE. The apC or iSTARalso reports tamper, input supervision errors, and communication failures.ViolatedAn intrusion zone changes from normal to violated when the system detects anintrusion zone violation. Violations include:• Hardware tamper or communication failure• Supervision errors for intrusion zone inputs or tamper inputs• Inputs that activate while the zone is armed. (If the zone is disarmedwithin the entrance delay, the violation does not occur.)• Doors that open while the zone is armed. (If the zone is disarmed withinthe entrance delay, the violation does not occur.)When the system detects an intrusion zone violation, the apC or iSTARchanges the status of the intrusion zone to violated and notifies C•CURE <strong>800</strong>/<strong>800</strong>0 of the violation. The server records the violation in the journal andgenerates an activity message at the Monitoring Station.If the intrusion zone includes an activity, such as flashing lights, assigned tothe “Event (Output) to activate while violated” status, the system initiates theactivity while the intrusion zone is violated.The intrusion zone status remains violated — whether or not the objectcausing the violation returns to the normal state — until you change the modeof the intrusion zone to Armed or Disarmed.You can change the mode to Armed via key-press/active input and cardswipe, or via an Arm selected manual action from the Monitoring Station.12–4 C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Software</strong> <strong>Configuration</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!