<strong>Junos</strong> <strong>OS</strong> 12.1 <strong>Interfaces</strong> <strong>Command</strong> <strong>Reference</strong><br />

Table 31: show interfaces Gigabit Ethernet Output Fields (continued)<br />

Field Name<br />

WIS section<br />

WIS line<br />

222<br />

Field Description<br />

(10-Gigabit Ethernet interfaces, WAN PHY mode) SONET error information:<br />

• Seconds—Number of seconds the defect has been active.<br />

• Count—Number of times that the defect has gone from inactive to active.<br />

• State—State of the error. Any state other than OK indicates a problem.<br />

Subfields are:<br />

• BIP-B1—Bit interleaved parity for SONET section overhead<br />

• SEF—Severely errored framing<br />

• LOL—Loss of light<br />

• LOF—Loss of frame<br />

• ES-S—Errored seconds (section)<br />

• SES-S—Severely errored seconds (section)<br />

• SEFS-S—Severely errored framing seconds (section)<br />

(10-Gigabit Ethernet interfaces, WAN PHY mode) Active alarms and defects,<br />

plus counts of specific SONET errors with detailed information.<br />

• Seconds—Number of seconds the defect has been active.<br />

• Count—Number of times that the defect has gone from inactive to active.<br />

• State—State of the error. State other than OK indicates a problem.<br />

Subfields are:<br />

• BIP-B2—Bit interleaved parity for SONET line overhead<br />

• REI-L—Remote error indication (near-end line)<br />

• RDI-L—Remote defect indication (near-end line)<br />

• AIS-L—Alarm indication signal (near-end line)<br />

• BERR-SF—Bit error rate fault (signal failure)<br />

• BERR-SD—Bit error rate defect (signal degradation)<br />

• ES-L—Errored seconds (near-end line)<br />

• SES-L—Severely errored seconds (near-end line)<br />

• UAS-L—Unavailable seconds (near-end line)<br />

• ES-LFE—Errored seconds (far-end line)<br />

• SES-LFE—Severely errored seconds (far-end line)<br />

• UAS-LFE—Unavailable seconds (far-end line)<br />