Table 73: T1 or E1 show interfaces Output Fields (continued)<br />

Field Name<br />

DS1 alarms<br />

DS1 defects<br />

T1 media or E1<br />

media<br />

Field Description<br />

E1 media-specific defects that can prevent the interface from passing packets.<br />

When a defect persists for a certain amount of time, it is promoted to an alarm.<br />

Based on the router configuration, an alarm can ring the red or yellow alarm<br />

bell on the router, or turn on the red or yellow alarm LED on the craft interface.<br />

The following lists all possible alarms and defects. For complete explanations<br />

of most of these alarms and defects, see Bellcore Telcordia GR-499-CORE.<br />

• AIS—Alarm indication signal.<br />

• LOF—Loss of frame.<br />

• L<strong>OS</strong>—Loss of signal.<br />

• YLW—Yellow alarm. Indicates errors at the remote site receiver.<br />

Counts of T1 or E1 media-specific errors.<br />

• Seconds—Number of seconds the defect has been active.<br />

• Count—Number of times that the defect has gone from inactive to active.<br />

• State—State of the error. State other than OK indicates a problem.<br />

The T1 or E1 media-specific error types are:<br />

• SEF—Severely errored framing<br />

• BEE—Bit error<br />

• AIS—Alarm indication signal<br />

• LOF—Loss of frame<br />

• L<strong>OS</strong>—Loss of signal<br />

• YELLOW—Errors at the remote site receiver<br />

• CRC Major—Cyclic redundancy check major alarm threshold exceeded<br />

• CRC Minor—Cyclic redundancy check minor alarm threshold exceeded<br />

• BPV—Bipolar violation<br />

• EXZ—Excessive zeros<br />

• LCV—Line code violation<br />

• PCV—Pulse code violation<br />

• CS—Carrier state<br />

• CRC—Cyclic redundancy check<br />

• FEBE—Far-end block error (E1 only)<br />

• LES—Line error seconds<br />

• ES—Errored seconds<br />

• BES—Bit error seconds<br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.<br />

• SES—Severely errored seconds<br />

• SEFS—Severely errored framing seconds<br />

• UAS—Unavailable seconds<br />

Chapter 6: Digital Transmission Interface Operational Mode <strong>Command</strong>s<br />

Level of Output<br />

detail extensive none<br />

extensive<br />