Table 99: OC192 PIC with XFP show interfaces diagnostics optics Output Fields (continued)<br />

Field Name<br />

Laser output power high<br />

warning threshold<br />

Laser output power low<br />

warning threshold<br />

Module temperature<br />

high alarm threshold<br />

Module temperature<br />

low alarm threshold<br />

Module temperature<br />

high warning threshold<br />

Module temperature<br />

low warning threshold<br />

Laser rx power high<br />

alarm threshold<br />

Laser rx power low<br />

alarm threshold<br />

Laser rx power high<br />

warning threshold<br />

Laser rx power low<br />

warning threshold<br />

Sample Output<br />

568<br />

show interfaces<br />

diagnostics optics<br />

(OC768 PIC)<br />

Field Description<br />

Vendor-specified threshold for the laser output power high warning: 0.7940 mW or -100 dBm.<br />

Vendor-specified threshold for the laser output power low warning: 0.2510 mW or -600dBm.<br />

Vendor-specified threshold for the module temperature high alarm: 90 °C or 194 °F.<br />

Vendor-specified threshold for the module temperature low alarm: -5 °C or 23 °F.<br />

Vendor-specified threshold for the module temperature high warning: 85 °C or 185 °F.<br />

Vendor-specified threshold for the module temperature low warning: 0 °C or 32 °F.<br />

Vendor-specified threshold for the laser Rx power high alarm: 1.2589 mW or 1.00 dBm.<br />

Vendor-specified threshold for the laser Rx power low alarm: 0.0323 mW or -14.91 dBm.<br />

Vendor-specified threshold for the laser Rx power high warning: 1.1220 mW or 0.50 dBm.<br />

Vendor-specified threshold for the laser Rx power low warning: 0.0363 mW or -14.40 dBm.<br />

user@host> show interfaces diagnostics optics so-4/0/0<br />

Physical interface: so-4/0/0<br />

Laser bias current : 79.938 mA<br />

Laser output power : 1.592 mW / 2.02 dBm<br />

Receiver signal average optical power : 1.3854 mW / 1.42 dBm<br />

Laser end-of-life alarm : Off<br />

Laser wavelength alarm : Off<br />

Laser bias current alarm : Off<br />

Laser temperature alarm : Off<br />

Laser power alarm : Off<br />

Modulator temperature alarm : Off<br />

Modulator bias alarm : Off<br />

Tx multiplexer FIFO error alarm : Off<br />

Tx loss of PLL lock alarm : Off<br />

Rx loss of average optical power alarm: Off<br />

Rx loss of AC power alarm : Off<br />

Rx loss of PLL lock alarm : Off<br />