Table 98: Multi-rate SONET/SDH PICs with SFP show interfaces diagnostics optics Output<br />

Fields (continued)<br />

Field Name<br />

Module temperature<br />

high alarm threshold<br />

Module temperature<br />

low alarm threshold<br />

Module temperature<br />

high warning threshold<br />

Module temperature<br />

low warning threshold<br />

Module voltage high<br />

alarm threshold<br />

Module voltage low<br />

alarm threshold<br />

Module voltage high<br />

warning threshold<br />

Module voltage low<br />

warning threshold<br />

Laser rx power high<br />

alarm threshold<br />

Laser rx power low<br />

alarm threshold<br />

Laser rx power high<br />

warning threshold<br />

Laser rx power low<br />

warning threshold<br />

Field Description<br />

Vendor-specified threshold for the module temperature high alarm: 110° C or 230° F.<br />

Vendor-specified threshold for the module temperature low alarm: -40° C or -40° F.<br />

Vendor-specified threshold for the module temperature high warning: 93° C or 199° F.<br />

Vendor-specified threshold for the module temperature low warning: -30° C or -22° F.<br />

Module voltage high alarm threshold: 3.900 v.<br />

Module voltage low alarm threshold: 2.700 v.<br />

Module voltage high warning threshold: 3.700 v.<br />

Module voltage high warning threshold: 2.900 v.<br />

Vendor-specified threshold for the laser Rx power high alarm: 1.1749 mW or 0.70 dBm.<br />

Vendor-specified threshold for the laser Rx power low alarm: 0.0039 mW or -24.09 dBm.<br />

Vendor-specified threshold for the laser Rx power high warning: 0.7942 mW or 1.00 dBm.<br />

Vendor-specified threshold for the laser Rx power low warning: 0.0100 mW or -20.00 dBm.<br />

Table 99 on page 565 lists the output fields for the show interfaces diagnostics optics<br />

command for OC192 PICs with XFP transceivers. Output fields are listed in the<br />

approximate order in which they appear.<br />

Table 99: OC192 PIC with XFP show interfaces diagnostics optics Output Fields<br />

Field Name<br />

Physical interface<br />

Link<br />

Field Description<br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.<br />

Name of the physical interface.<br />

Chapter 11: SONET/SDH Interface Operational Mode <strong>Command</strong>s<br />

(For 4-port OC192c PIC operating in OC768-over-4xOC192 mode) The link number. Diagnostics and<br />

alarms are displayed for each link.<br />

565

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!