<strong>Junos</strong> <strong>OS</strong> 12.1 <strong>Interfaces</strong> <strong>Command</strong> <strong>Reference</strong><br />

Table 38: 10-Gigabit Ethernet Transceivers show interfaces diagnostics optics Output<br />

Fields (continued)<br />

Field Name<br />

Module temperature<br />

high alarm threshold<br />

Module temperature<br />

low alarm threshold<br />

Laser rx power high<br />

alarm threshold<br />

Laser rx power low<br />

alarm threshold<br />

Laser bias current high<br />

warning threshold<br />

Laser bias current low<br />

warning threshold<br />

Laser output power high<br />

warning threshold<br />

Laser output power low<br />

warning threshold<br />

Module temperature<br />

high warning threshold<br />

Module temperature<br />

low warning threshold<br />

Laser rx power high<br />

warning threshold<br />

Laser rx power low<br />

warning threshold<br />

Field Description<br />

Module temperature high alarm threshold. Alarm threshold ranges are vendor-specific.<br />

Module temperature low alarm threshold. Alarm threshold ranges are vendor-specific.<br />

Laser receive power high alarm threshold. Alarm threshold ranges are vendor-specific.<br />

Laser receive power low alarm threshold. Alarm threshold ranges are vendor-specific.<br />

Laser bias current high warning threshold. Warning ranges are vendor-specific.<br />

Laser bias current low warning threshold. Warning ranges are vendor-specific.<br />

Laser output power high warning threshold. Warning ranges are vendor-specific.<br />

Laser output power low warning threshold. Warning ranges are vendor-specific.<br />

Module temperature high warning threshold. Warning ranges are vendor-specific.<br />

Module temperature low warning threshold. Warning ranges are vendor-specific.<br />

Laser receive power high warning threshold. Warning threshold ranges are vendor-specific.<br />

Laser receive power low warning threshold. Warning threshold ranges are vendor-specific.<br />

Table 39 on page 270 lists the output fields for the show interfaces diagnostics optics<br />

command for XFP transceivers. Output fields are listed in the approximate order in which<br />

they appear.<br />

Table 39: 10-Gigabit Ethernet XFP Transceivers show interfaces diagnostics optics Output<br />

Fields<br />

Field Name<br />

Physical interface<br />

270<br />

Field Description<br />

Name of the physical interface.<br />