<strong>ITALY</strong> - 4 Wastewater<br />

Parameter # Parameter (1)<br />

49.4 1,4<br />

Dichlorobenzene<br />

49.5 1,1<br />

Dichloroethylene<br />

49.6 1,2<br />

Dichloroethylene<br />

49.7 Tetrachloroethyle<br />

ne<br />

Unit of<br />

Measure<br />

Discharge into Surface Water<br />

A B C D E<br />

mg/L 0.3 0.003<br />

mg/L 1 0.01<br />

mg/L 1 0.01<br />

mg/L 0.5 0.005<br />

49.8 Trichloroethylene mg/L 1 0.01<br />

49.9 Carbon<br />

Tetrachloride<br />

49.10 Sum of Carbon<br />

Sulfur,<br />

Trichloroethylene,<br />

Chloroform,<br />

Carbon<br />

Tetrachloride,<br />

Dichloroethylene<br />

49.11 Other non<br />

mentioned organic<br />

compounds<br />

(pesticides,<br />

solvents,<br />

plastifiers etc.)<br />

50 Escherichia coli UFC/100<br />

ml<br />

51 Acute Toxicity<br />

Test (21)<br />

mg/L 1 0.01<br />

mg/L 2<br />

mg/L 0.1<br />

5000 (21) 5000 (21) 5000 (21) 5000 (21) (19) (21)<br />

5000<br />

LC50 24h 50%<br />

survival after<br />

24 hours<br />

50%<br />

survival after<br />

24 hours<br />

50%<br />

survival<br />

after 24<br />

hours<br />

Notes:<br />

(1) Analysis of discharges derived from lagooning or phytopurification should be made on filtered samples. The<br />

suspended solids concentration shall not exceed 150 mg/L.<br />

(2) pH values of the receptor shall be in the range of 6.5-8.5 within 50 m from the discharge.<br />

(3) For watercourses, the maximum variation from the average temperature of any section upstream or downstream<br />

of the discharge point shall not exceed 3°C. On at least half of any downstream section of the discharge point,<br />

the variation shall not exceed 1°C.<br />

For lakes, the discharge temperature shall not exceed 30°C, while the temperature increase of the receiving<br />

water body shall not exceed 3°C at a distance of 50 meters from the discharge point.<br />

For artificial canals, the maximum average value of water temperature in any section, shall not exceed 35°C.<br />

This condition is subject to the approval of the canals’ administrator.<br />

For sea and outlet zones of non-significant streams, the discharge temperature shall not exceed 35°C, and the<br />

temperature increase of the receiving water body shall not exceed 3°C at a distance of 1,000 meters from the<br />

discharge point. The environmental compatibility of the discharge with the receiving body shall be ensured,<br />

and the formation of thermal barriers shall be avoided at river outlets.<br />

(4) Temperature increase of the receptor shall not exceed 3°C in the first 2m (from the water surface) at 1,000 m<br />

from the discharge.<br />

September 2012 Italy FGS 4-28<br />