<strong>ITALY</strong> - 18 Spill Prevention and Response Planning<br />

Parameter<br />

Recreation,<br />

Private, and<br />

Residential Use<br />

September 2012 Italy FGS 18-9<br />

Revision 0<br />

Soil<br />

Commercial and<br />

Industrial Use Groundwater 2<br />

2,4-Dichlorophenol 0.5 50 110<br />

Pentachlorophenol 0.01 5 0.5<br />

2,4,6-Trichlorophenol 0.01 5 5<br />

Aromatic Amines<br />

Aniline 0.05 5 10<br />

Diphenylamine 0.1 10 910<br />

p-Toluidine 0.1 5 0.35<br />

m-Anisidine 0.1 10 NA<br />

p-Anisidine 0.1 10 NA<br />

Sum of Aromatic Amines (73-77) 0.5 25 NA<br />

Pesticides<br />

Alachlor 0.01 1 0.1<br />

Aldrin 0.01 0.1 0.03<br />

Atrazine 0.01 1 0.3<br />

Chlordane 0.01 0.1 0.1<br />

DDD, DDT, DDE 0.01 0.1 0.1<br />

Dieldrin 0.01 0.1 0.03<br />

Endrin 0.01 2 0.1<br />

-Lindane 0.01 0.1 0.1<br />

-Lindane 0.01 0.5 0.1<br />

-Lindane 0.01 0.5 0.1<br />

Sum of Pesticides NA NA 0.5<br />

Dioxins and Furans<br />

PCBs 0.06 5 0.01<br />

Sum of PCDD and PCDF<br />

(TEF conversion)<br />

1 x 10 -5 1 x 10 -4 4 x 10 -6<br />

Hydrocarbons<br />

C≤12 10 250 NA<br />

C>12<br />

Other Compounds<br />

50 750 NA<br />

Asbestos (Fibers A > 10 mm) 1,000* 1,000* NA<br />

Acrylamide NA NA 0.1<br />

n-Hexane NA NA 350<br />

para-Phthalic Acid NA NA 37,000<br />

Phthalic Acid Ester (each) 10 60 NA<br />

Notes:<br />

1 The table includes, for each chemical category, compounds that are frequently encountered at contaminated<br />

sites. For those compounds not specifically included in this table, the maximum concentration limits are<br />

derived by comparison with the compound more similar toxicologically.<br />

2 In those cases when the regulations for the protection of water from pollution include different values than<br />

those reported in this table and specify a timeframe to achieve these concentrations, the values of this table<br />

are replaced by those in the regulations and the approval of remedial projects must take into consideration<br />

these values and the implementation of applicable deadlines.<br />

* Corresponding to the analytical method detection limit.