<strong>ITALY</strong> - 4 Wastewater<br />

(3) The above limits are not valid for discharges to the sea. Inlet areas are comparable to coastal seawaters,<br />

provided that on at least half of any section downstream of the discharge, the natural variations of sulfates and<br />

chlorides are not altered.<br />

(4) During the permitting process of the urban wastewater treatment system, the Competent Authority will set the<br />

most appropriate limit according to the environmental and hygienic-sanitary conditions of the surface water<br />

receptor and according to the existing uses. A limit not exceeding 5,000 UFC/100 ml is advised.<br />

(5) The toxicity test is mandatory. In addition to the Daphnia magna test, an acute toxicity test may be conducted<br />

on Ceriodaphnia dubia, Selenastrum capricornutum, bioluminescent bacteria or organisms such as Artemia<br />

salina, for salty water discharges or other organisms. If different toxicity tests are performed, the worst result<br />

will be considered. The positive result of the toxicity test does not imply the direct application of the sanctions<br />

but it requires an in-depth review of the analytical results to determine the origin of the toxicity levels and their<br />

subsequent removal.<br />

(6) Such substance shall be absent from the recovered wastewater dedicated to reuse, according to what set the<br />

applicable limits for the wastewater discharge to soil. Such prescription is intended as compliant when the<br />

substance is present in a concentration lower than detectable limits of the reference analytic methodologies, still<br />

to be defined and updated. In the absence of this definition, the applicable limits are the detectable limits of the<br />

table.<br />

(7) The parameter value is referred to each single pesticide. In case of Aldrin, Dieldrin, Epta chlorine and Epossidic<br />

Epta chlorine, the parametric value is 0.030 mu/g/l.<br />

(8) For the recovered wastewaters coming from lagooning or phyto-depuration the applicable limits are those are<br />

50 UFC/100 ml (80% of samples) and 200 UFC/100 ml (maximum punctual value).<br />

(9) More stringent limits could be applied by the final depending on process requirements.<br />

(10) In case of exceedance of threshold limits, the reuse shall be immediately interrupted and could be started again<br />

only after the value of the parameter(s) is(are) compliant for the subsequent three consecutive samples<br />

(11)Reported values may be defined differently at the Regional level l.<br />

(12) In case of irrigation reuse values for total phosphorus and total nitrogen can be raised to 10 and 35 mg/l<br />

respectively.<br />

(13) In case of irrigation and civil use or chemical physical parameters threshold limits are set for annual average<br />

values. In case of irrigation use threshold limits are set for each irrigation campaign. The reuse shall be however<br />

immediately interrupted if the value of whichever parameter is > 100% of the threshold limit as for this Table.<br />

(14) For Salmonella parameter the threshold limit is to be referred to 100% of samples. The reuse shall be however<br />

immediately interrupted if Salmonella is detected.<br />